I am receiving an error message on my Cat 6500
%CDP-4-NVLANMISMATCH:Native vlan mismatch detected .
It is connected to an Alteon AD2..
Any Ideas
Thanks
__
Do You Yahoo!?
Get personalized email addresses from Yahoo! Mail
Filippelli
Sent: Tuesday, July 03, 2001 1:32 PM
To: [EMAIL PROTECTED]
Subject: Catalyst 6500 Alteon [7:10895]
I am receiving an error message on my Cat 6500
%CDP-4-NVLANMISMATCH:Native vlan mismatch detected .
It is connected to an Alteon AD2..
Any Ideas
Thanks
Mobile:
Alpha Page:
Mailing:1360 Post Oak Blvd
Suite 500
Houston, TX 77056
-Original Message-
From: Ralph Filippelli [mailto:[EMAIL PROTECTED]]
Sent: Tuesday, July 03, 2001 3:32 PM
To: [EMAIL PROTECTED]
Subject: Catalyst 6500 Alteon [7
Ralph,
I've gotten this message before myself. It occurred when the two ports that
made up a trunk link had different native VLANs. Changing the native VLAN of
one of the ports to match the other allowed the trunk link to come up. I
Imagine that your situation is likely quite similar. just check
You need to worry about native vlans if you're doing
802.1q trunking.
It is trying to talk CDPv2 to the Alteons and probably
expecting something back. Just turn off CDP since you
won't need it with Alteons anyway. At least I don't
think so, unless Alteons do 802.1q trunking.
If they do, then
5 matches