Catalyst 6500 Alteon [7:10895]

2001-07-03 Thread Ralph Filippelli
I am receiving an error message on my Cat 6500 %CDP-4-NVLANMISMATCH:Native vlan mismatch detected . It is connected to an Alteon AD2.. Any Ideas Thanks __ Do You Yahoo!? Get personalized email addresses from Yahoo! Mail

RE: Catalyst 6500 Alteon [7:10895]

2001-07-03 Thread David Wolsefer
Filippelli Sent: Tuesday, July 03, 2001 1:32 PM To: [EMAIL PROTECTED] Subject: Catalyst 6500 Alteon [7:10895] I am receiving an error message on my Cat 6500 %CDP-4-NVLANMISMATCH:Native vlan mismatch detected . It is connected to an Alteon AD2.. Any Ideas Thanks

RE: Catalyst 6500 Alteon [7:10895]

2001-07-03 Thread Buri, Heather H
Mobile: Alpha Page: Mailing:1360 Post Oak Blvd Suite 500 Houston, TX 77056 -Original Message- From: Ralph Filippelli [mailto:[EMAIL PROTECTED]] Sent: Tuesday, July 03, 2001 3:32 PM To: [EMAIL PROTECTED] Subject: Catalyst 6500 Alteon [7

Re: Catalyst 6500 Alteon [7:10895]

2001-07-03 Thread Karen E Young
Ralph, I've gotten this message before myself. It occurred when the two ports that made up a trunk link had different native VLANs. Changing the native VLAN of one of the ports to match the other allowed the trunk link to come up. I Imagine that your situation is likely quite similar. just check

Re: Catalyst 6500 Alteon [7:10895]

2001-07-03 Thread Yonkerbonk
You need to worry about native vlans if you're doing 802.1q trunking. It is trying to talk CDPv2 to the Alteons and probably expecting something back. Just turn off CDP since you won't need it with Alteons anyway. At least I don't think so, unless Alteons do 802.1q trunking. If they do, then