HSRP Betweem 6509 MSFC Blades

2000-11-03 Thread Rossetti, Stan
Could someone tell me if they have seen this problem before or have any suggestions. Scenario: We have 2 6509 switches with msfc cards in each on the 1st floor and 4th floor of a building. We have redundant links between the switches and each switch has redundant sup 1 cards with the msfc

Re: HSRP Betweem 6509 MSFC Blades

2000-11-03 Thread Rodgers Moore
Stan, Without seeing configs it's a little hard to diagnose, but two things come to mind. Preempt on HSRP. Are you using it? Second, it sounds like you have layer two redunancy, so spanning tree should have a link in Blocking mode. When you test a failure, this link will start forwarding

Re: HSRP Betweem 6509 MSFC Blades

2000-11-03 Thread Scott M. Trieste
Stan, Trunk your 6509's, ISL/On. Don't use spanning tree between your Switches. HSRP between your MSFC Cards will suffice. Can you post your configs, I'm sure we can help. Thanks. -Scott ""Rossetti, Stan"" [EMAIL PROTECTED] wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]...