In article , [EMAIL PROTECTED]
says...
Hi,
In a Stataful configuration, and two PIX are interconnected via a
dedicated Failover Fastethernet, in case of the Active unit's Internal
interface fails, is there any method to shift traffic to the Standby
unit's Internal interface to maintain
Speaking of stateful PIX's, if I make a change on 1 PIX, and it has failover
on, will it automatically make a change on the other PIX?
Gaz wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
In article , [EMAIL PROTECTED]
says...
Hi,
In a Stataful configuration, and two PIX
Whenever you type a command on the active unit it's being replicated to the
standby
unit. So yes, it will automatically update standby unit but it's not written
to memory
unless you write to memory on the active first.
Steven A. Ridder wrote in message
[EMAIL PROTECTED]">news:[EMAIL
yes, it will sync automatically, or you can force it
with write standby
HTH,
ms
--- Steven A. Ridder wrote:
Speaking of stateful PIX's, if I make a change on 1
PIX, and it has failover
on, will it automatically make a change on the other
PIX?
Gaz wrote in message
[EMAIL
Hi,
In a Stataful configuration, and two PIX are interconnected via a
dedicated Failover Fastethernet, in case of the Active unit's Internal
interface fails, is there any method to shift traffic to the Standby
unit's Internal interface to maintain connectivity, thanks.
Leo
Best Regards.
Message -
From: Leo Song
To:
Sent: Thursday, August 15, 2002 9:21 PM
Subject: PIX Failover [7:51491]
Hi,
In a Stataful configuration, and two PIX are interconnected via a
dedicated Failover Fastethernet, in case of the Active unit's Internal
interface fails, is there any method to shift
6 matches