RE: PVC status don't go down [7:35389]

2002-02-17 Thread Anthony Toh
I thks to all who come to advise, really appreciate. Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=35662t=35389 -- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and

RE: PVC status don't go down [7:35389]

2002-02-16 Thread Nick S.
Ok, The PVC status would never go down till the switch reports it as down, and only then will the line protocol go down. I have come across this scenario a couple of times (with ATM, concept is the same). And the trick is to use a routing protocol between the 2 routers, a routing protocol senses

RE: PVC status don't go down [7:35389]

2002-02-16 Thread Erick B.
You could also use Frame-Relay End-To-End keepalives (FREEK). This works best if a subinterface is used. --- Nick S. wrote: Ok, The PVC status would never go down till the switch reports it as down, and only then will the line protocol go down. I have come across this scenario a couple of

RE: PVC status don't go down [7:35389]

2002-02-15 Thread Anthony Toh
You see Eric, because I have an ISDN line as backup, that's why I need both routers to see the PVC as down for any failure that happen on either side. In that case, both routers can then activate the ISDN from either side and use the backup route properly. Now, with router B not able to see the

PVC status don't go down [7:35389]

2002-02-14 Thread Anthony Toh
Can anyone enlight me on this. I have 2 sites connected through a Frame Relay network as below : Router A Frame Relay Router B My question is this when interface of router A goes down, router B cannot notice it and the whole PVC is not updated as down. But when the interfaces of both

Re: PVC status don't go down [7:35389]

2002-02-14 Thread [EMAIL PROTECTED]
Anthony Toh cc: Sent by: Subject: PVC status don't go down [7:35389] nobody@groupstu dy.com