essage-
From: Steve Lilley [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, January 22, 2003 7:56 AM
To: Frank Jimenez; [EMAIL PROTECTED]
Subject: Re: Cat6500 PSU interoperability [7:60949]
We are successfully mixing 1300W and 2500W power supplies in the
Cat6500s in our labs. We are running 6.3
We are successfully mixing 1300W and 2500W power supplies in the
Cat6500s in our labs. We are running 6.3.3a on the switches,
and power redundancy is functioning fine (even though the Cisco
docs say it shouldn't):
6506_1> (enable) sh vers
WS-C6506 Software, Version NmpSW: 6.3(3a)
Copyright (c) 1
Many thanks to all that responded.
Andrew
-Original Message-
From: Frank Jimenez [mailto:[EMAIL PROTECTED]]
Sent: 13 January 2003 18:36
To: 'Andrew Larkins'; [EMAIL PROTECTED]
Subject: RE: Cat6500 PSU interoperability [7:60949]
Yes and no.
In combined mode they may be
Yes and no.
In combined mode they may be different wattages.
In redundant mode wattages must be identical.
More detail at:
http://www.cisco.com/en/US/partner/products/hw/switches/ps708/products_c
onfiguration_guide_chapter09186a008007e6f6.html
Frank Jimenez, CCIE #5738
[EMAIL PROTECTED]
-O
4 matches
Mail list logo