RE: Cat6500 PSU interoperability [7:60949]

2003-01-22 Thread Frank Jimenez
essage- From: Steve Lilley [mailto:[EMAIL PROTECTED]] Sent: Wednesday, January 22, 2003 7:56 AM To: Frank Jimenez; [EMAIL PROTECTED] Subject: Re: Cat6500 PSU interoperability [7:60949] We are successfully mixing 1300W and 2500W power supplies in the Cat6500s in our labs. We are running 6.3

Re: Cat6500 PSU interoperability [7:60949]

2003-01-22 Thread Steve Lilley
We are successfully mixing 1300W and 2500W power supplies in the Cat6500s in our labs. We are running 6.3.3a on the switches, and power redundancy is functioning fine (even though the Cisco docs say it shouldn't): 6506_1> (enable) sh vers WS-C6506 Software, Version NmpSW: 6.3(3a) Copyright (c) 1

RE: Cat6500 PSU interoperability [7:60949]

2003-01-14 Thread Andrew Larkins
Many thanks to all that responded. Andrew -Original Message- From: Frank Jimenez [mailto:[EMAIL PROTECTED]] Sent: 13 January 2003 18:36 To: 'Andrew Larkins'; [EMAIL PROTECTED] Subject: RE: Cat6500 PSU interoperability [7:60949] Yes and no. In combined mode they may be

RE: Cat6500 PSU interoperability [7:60949]

2003-01-13 Thread Frank Jimenez
Yes and no. In combined mode they may be different wattages. In redundant mode wattages must be identical. More detail at: http://www.cisco.com/en/US/partner/products/hw/switches/ps708/products_c onfiguration_guide_chapter09186a008007e6f6.html Frank Jimenez, CCIE #5738 [EMAIL PROTECTED] -O