RE: Issue with 6509 [7:71468]

2003-06-26 Thread Larry Letterman
Line card in slot 6 is bad, replace it..the error is related to a Hardware failure on the board... Larry Letterman Cisco Systems -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of [EMAIL PROTECTED] Sent: Thursday, June 26, 2003 12:07 PM To: [EMAIL PROTEC

RE: Issue with 6509 [7:71468]

2003-06-26 Thread Salvatore De Luca
You have a BAD ASIC on your module. RMA baby! What kind of module is it? I have seen many issues with the 6348 blades as ASIC's failing. With the 6348 mod, ASIC's come in 12 port clusters per ASIC.. when the ASIC's fail to process, you get Coil errors.. You can either, move your connections to

Re: Issue with 6509 [7:71468]

2003-06-26 Thread MADMAN
1. %SYS-3-SYS_LCPERR3:Module [dec]: Bus Asic #[dec] out of sync error This message indicates a multiple-synchronization problem between the bus ASIC and the port ASIC. The first [dec] is the module number. The second [dec] is the ASIC number. Recommended Action: Replace the module if the error

Re: Issue with 6509 [7:71468]

2003-06-26 Thread [EMAIL PROTECTED]
Mario, Found this through the Cisco Output Interpreter: %SYS-3-SYS_LCPERR3 (x0):Module [dec]: Coil Pb Tx Underflow Error - Port #dec] Explanation: This message indicates an underflow in the port ASIC transmit buffer. The first [dec] is the module number. The second [dec] is the ASIC port numbe

Re: Issue with 6509 [7:71468]

2003-06-26 Thread dre
wrote in message... > Having a problem with 12 ports on one of our 6509's.. They are unable to > pass traffic, and I get the following errors on the console. > > 2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow > Error - Port #2: I'm surpised at all the poor responses to this

Re: Issue with 6509 [7:71468]

2003-06-26 Thread David Vital
Hey that's a good trick to throw in the Bag. I havn't had this problem happen yet. the only problem I have had from the 6509's is a Belly up sup mod. Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=71502&t=71468 -- FAQ, list archiv

RE: Issue with 6509 [7:71468]

2003-06-27 Thread Kaminski, Shawn G
2003 11:36 PM To: [EMAIL PROTECTED] Subject: Re: Issue with 6509 [7:71468] Hey that's a good trick to throw in the Bag. I havn't had this problem happen yet. the only problem I have had from the 6509's is a Belly up sup mod. Message Posted at: http://www.groupstu

RE: Issue with 6509 [7:71468]

2003-06-30 Thread Peri Sophos
Explanation This message indicates an underflow in the port ASIC transmit buffer. The first [dec] is the module number. The second [dec] is the ASIC port number. Action If the error is limited to a single module, replace the module. If the error occurs several times, contact your technical suppo