RE: Unicast flooding on switch ports [7:52907]

2002-09-09 Thread David C Prall
Have a look here. The quickest fix is to change the ARP timers to 180 seconds. This will be less then the 5 minute CAM timers. http://www.cisco.com/warp/public/473/62.shtml#casestudy8 -- David C Prall [EMAIL PROTECTED] http://dcp.dcptech.com > -Original Message- > From: Hitesh Pathak R

Re: Unicast flooding on switch ports [7:52907]

2002-09-09 Thread Cisco_Maniac
Hi Hitesh, I feel this traffic could be the replication traffic between the two Win2K server. What are the nature of the two servers? Also if possible edit and paste the output of the sniffer. This would help us decipher what is actually happening. Do you get any such statistics in traffic from A

Re: Unicast flooding on switch ports [7:52907]

2002-09-09 Thread Darrell Newcomb
Well I had an early Cat6k with Sup1 and a software bug which caused the L2 CAM not to populate. Simple software upgrade resolved the problem, been too long for me to recall which CatOS version that would have been. I doubt that's what you're facing, but since you asked for examples :-) Fir