RE: weird switch! can't config thru console [7:13302]

2001-07-23 Thread Remmert Veen
Hi Tong, What you might wanna do is try to login at different speed settings. I've had the same problem once and it took me a long time to find out that somebody else had changed the speed setting to 115k (for a file transfer via console) and never changed it back. Hth, Remmert Message Posted

RE: weird switch! can't config thru console [7:13302]

2001-07-23 Thread Ole Drews Jensen
If you cable works with the other switches, you can try to change the flow control to NONE instead of HARDWARE. Most of the Cisco devices I have worked with will accept HARDWARE flow control, but some few will not. If that does not work, I would suggest that you connect the new switch with one

RE: weird switch! can't config thru console [7:13302]

2001-07-23 Thread [EMAIL PROTECTED]
type of switch? 5500 use straight thru cable; however, and 6000 use that one and roll over, but you must push the botton to use either straight or roll over. If you cable works with the other switches, you can try to change the flow control to NONE instead of HARDWARE. Most of the Cisco