Re: Token Ring Module Problem for Catalyst 5000 [7:21610]

2001-10-02 Thread Tim Booth
ssage - From: "Ed Moss" To: Sent: Tuesday, October 02, 2001 4:58 PM Subject: Re: Token Ring Module Problem for Catalyst 5000 [7:21610] > The WS-X5030 Token Ring Module requires a Supervisor II to function. > A SUP I provides similar results to what you state the Cat keeps s

Re: Token Ring Module Problem for Catalyst 5000 [7:21610]

2001-10-02 Thread Ed Moss
The WS-X5030 Token Ring Module requires a Supervisor II to function. A SUP I provides similar results to what you state the Cat keeps saying the module is resetting or faulty. If you do a sho modules, or a show version, I believe the software/firmware versions will report 0.0. Ed Messag

Token Ring Module Problem for Catalyst 5000 [7:21610]

2001-10-01 Thread [EMAIL PROTECTED]
Hello, I ordered a Token Ring module from someone off ebay. I stuck it in my cat 5000 and it said that it had an invalid configuration (probably because there was just previously a different module in it) and the status was "faulty". I did a clear config all and reset, and it no longer said t