On May 26, 2015, at 5:42 PM, Phil Bedard phil...@gmail.com wrote:
We recently found out some of the FEX modules are also not supported yet on
the 9372. Things like dual homed FEX is also bot supported yet, but we were
aware of that. The 9300 if I'm not mistaken has the additional chip
Does this defeat the purpose of dns ? I mean if I want to use a hostname
for my syslog so that If I ever want to change the ip address of my syslog
server, it seems that this would break since IOS is apparently resolving the
name to a number and then putting the number in the config
Is there
Does this defeat the purpose of dns ? I mean if I want to use a hostname
for my syslog so that If I ever want to change the ip address of my syslog
server, it seems that this would break since IOS
Yes.
Is there a way to stop IOS from changing the name to a number and leave the
name in the
IOS does this all the time - for many features, not just this e.g. tunnel
destinations
Use an EMM script that rewrites the config, and does the lookup on the fly like
every few hours.
-Original Message-
From: cisco-nsp [mailto:cisco-nsp-boun...@puck.nether.net] On Behalf Of Lukas
Anybody have experience with network devices in covered areas not directly
exposed to the elements but exposed to external temperature variations?
Do I need an enclosure or is there exterior models that cam withstand the
elements?
Google-fu revealed Cisco 3010.
Mike
I have equipment in a small equipment shelter at the base of a 96 foot tall
tower. The equipment shelter is a small version of one of those wooden
storage sheds hardware places sell. At the other end of the link the
equipment is in a NEMA box rated to Type 4. The storage shed has one screen
type
Hello all,
ASR920 seems to support mLACP with the Advanced Metro IP License.
Has anyone experienced issues while using it in production network?
I'm specifically interested in VPWS, where two Active/Active or
Active/Standby pseudowires from a UNI are terminating on a couple of ASR920
We use the IE-3000 series which is smaller than the IE-3010 and probably cost
less.
The temp ratings are similar, noting that your temp is governed by enclosure
type.
A vented or fan equipped enclosure is needed to get maximum temperature rating.
The IE-3000 is rated for higher altitude than the