Sweet, now maybe he can get off hotmail and then he would be the perfect
human being. ;)
Nice work out there A-a-ron!
On Fri, Jul 22, 2016 at 4:08 PM, Ryan Huff wrote:
> Hello everyone,
>
> I'll start by saying that since I have listened to this list, I've not
> seen this -so I am not sure if
Hello everyone,
I'll start by saying that since I have listened to this list, I've not
seen this -so I am not sure if this is frowned upon by list maintainers
or not (please unicast me if it is).
I would like to give a virtual "Industry Hi-Five" to Aaron Banks for a
job well done! Aaron and I
Figured it out. In my UCCX script, my ECC variable was strConcatenated - it
was missing "user" on the front of it. I renamed it to userstrConcatenated,
which fixed it. But, a typical concatenated string was about 230 characters.
The maximum length of an ECC variable is 210 characters. So, I
It looks like you need one of the audio input modules for that controller-
http://www.logison.com/components/paging-and-music-components.html
You'll want the telephone one.
As Mike said, supervisor disconnect is only something you need to worry
about when it won't cut off the page after completed
If the paging controller is taking the ATA off-hook as soon as you plug it in,
then it sounds to me like the interface on the paging controller is the wrong
kind of interface (perhaps needs to be configured).
Disconnect supervision issues would show up *after* making an announcement, but
you ar
Which input on the Logison NCP are you hooked up to? It sounds like maybe
the microphone or AUX input rather than the telephone input as it shouldn't
play anything through the speakers until it detects ringing voltage and
then goes off-hook. It may be that this thing needs an FXO port instead.
Ha
Hi everyone,
I'm trying to connect an ATA 190 to a Logison Paging Module a vendor installed
to get paging functionality at a site. The vendor has stated the following:
"Upon dialing the specific extension assigned to paging, this line is "live"
(i.e. answers the line A.K.A. Auto Answer) to
Just giving an update, but still have a question on the Finesse workflow
action. I can get the HTTP request to work when sending in any of the custom
variables 1 to 10 in the body of the request. The web server I am sending the
HTTP request to requires all 10 custom variables, but a workflow a