Yes, you can do that. Thanks!
Karl
On Tue, Mar 15, 2022 at 2:19 PM Julien Massiera <
julien.massi...@francelabs.com> wrote:
> Then I'll create a ticket to just add a date to the system.err.println
> output of the OOM, is it ok ?
>
> -Message d'origine-
> De : Karl Wright
> Envoyé :
Then I'll create a ticket to just add a date to the system.err.println output
of the OOM, is it ok ?
-Message d'origine-
De : Karl Wright
Envoyé : mardi 15 mars 2022 19:10
À : dev
Objet : Re: Change way of logging OOM and InterruptedException in WorkerThread
(1)
(1) InterruptedExceptions are thrown during normal shutdown and should
generally not be logged. This is by design.
(2) OOM conditions can prevent logging from working. So if you want to log
those, fine, but please retain the System.err output.
Karl
On Tue, Mar 15, 2022 at 1:51 PM Julien
Hi,
In the WorkerThread class, OOM are logged using System.err (l849) and
therefore cannot be formated, but more importantly, the timestamp is lost,
which can be very problematic to investigate issues. Also,
InterruptedExceptions are not logged at all (l844) !
Can we use Logging.threads.fatal
[
https://issues.apache.org/jira/browse/CONNECTORS-1700?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Julien Massiera resolved CONNECTORS-1700.
-
Fix Version/s: ManifoldCF next
Resolution: Fixed
r1898949
>
Julien Massiera created CONNECTORS-1700:
---
Summary: TikaServiceRmeta: Add options to filter out metadata
based on size
Key: CONNECTORS-1700
URL: https://issues.apache.org/jira/browse/CONNECTORS-1700