Gabriel,
I didn't realize you were also tx'ing. You won't be able to go to an
interpolation of 1024 on the Tx side.
M
On 04/16/2016 09:37 AM, Gabriel Pechiarovich wrote:
> Hi I just tried your suggestion and it was ok for the RX side, but in
> the Tx side the decimation wont go up to 1024, it
Hi I just tried your suggestion and it was ok for the RX side, but in the
Tx side the decimation wont go up to 1024, it only decimates up to 512,
-- Asking for clock rate 16.384 MHz
-- Actually got clock rate 16.384 MHz
-- Performing timer loopback test... pass
-- Performing timer loopback
On 04/06/2016 10:26 PM, Martin Braun wrote:
> On the release 4 image, you can't do that. But you can set the clock to
> 16 MHz and use a decimation of 1000. Or you can use a clock rate of
> 16384e3 and a decimation of 1024, for a better decimation filter response.
...they'll probably be about the
On the release 4 image, you can't do that. But you can set the clock to
16 MHz and use a decimation of 1000. Or you can use a clock rate of
16384e3 and a decimation of 1024, for a better decimation filter response.
Cheers,
Martin
On 04/06/2016 06:11 PM, Gabriel Pechiarovich wrote:
> Hi, thanks
Hi, thanks for your answeri wasn't able to answer earlier.
I was aiming to a 8MHz clock rate in order to use the DDC and get a 16000
sample rate.
So i think i was misunderstood.
Thank you very much
Gabriel
2016-03-31 13:25 GMT-05:00 Martin Braun :
> On the release 4
On the release 4 image, you can't set the clock speed under 10 MHz.
However, you can use a DDC (which is built in and automatically used).
Simply set the clock rate to 32 MHz (or 16 MHz if this is MIMO) and the
sample rate to 8 MHz.
Cheers,
Martin
On 03/30/2016 05:02 PM, Gabriel Pechiarovich
Hi all,
I've developed a flowgraph wich includes a qpsk modulator and and audio
encoder, I used to run it in the E310 using the first release (
http://files.ettus.com/e3xx_images/e3xx-release-001/) and now trying to use
the release 4.
The problem is:
in the UHD sink and source the clock rate was