The regulator id is given without the "-supply" postfix. With that
fixed, the driver will look up the correct regulator from the device
tree.

Fixes: b26975593b17 ("display/drm/bridge: TC358775 DSI/LVDS driver")
Signed-off-by: Michael Walle <mwa...@kernel.org>
---
 drivers/gpu/drm/bridge/tc358775.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/gpu/drm/bridge/tc358775.c 
b/drivers/gpu/drm/bridge/tc358775.c
index 3b7cc3be2ccd..980f71ea5a6a 100644
--- a/drivers/gpu/drm/bridge/tc358775.c
+++ b/drivers/gpu/drm/bridge/tc358775.c
@@ -680,14 +680,14 @@ static int tc_probe(struct i2c_client *client)
        if (ret)
                return ret;
 
-       tc->vddio = devm_regulator_get(dev, "vddio-supply");
+       tc->vddio = devm_regulator_get(dev, "vddio");
        if (IS_ERR(tc->vddio)) {
                ret = PTR_ERR(tc->vddio);
                dev_err(dev, "vddio-supply not found\n");
                return ret;
        }
 
-       tc->vdd = devm_regulator_get(dev, "vdd-supply");
+       tc->vdd = devm_regulator_get(dev, "vdd");
        if (IS_ERR(tc->vdd)) {
                ret = PTR_ERR(tc->vdd);
                dev_err(dev, "vdd-supply not found\n");

-- 
2.39.2