Hi Doug,
Filter bandwidth is stored per-mode. At present, all data sub-modes
share the same bandwidth. I'll look at what would be required to split
them out.
Meanwhile, you could use the user-programmable NORM settings, 1 and 2,
to switch between two often-used bandwidths in DATA modes. See
Ok not sure if I am understanding this wrong or not... But I've
configured my M1-M4 as follows:
M1 = 14.0 - 14.15 - CW mode - width 350Hz
M2 = 14.15 - 14.35 - SSB mode - width 1.5K w/ a shift of .95
M3 = 14.03 - 0.000 - Data Mode (FSK D) - width 500Hz Dual PB
M4 = 14.03 - 14.06 - Data Mode (PSK D
Looks like you found a bug.
Perhaps someone can clarify / correct my use of the per-band quick memories.
I'm using M1 to M4 to save sub-band frequencies and filter positions with BW
settings in each of the bands 160 thru 10 and having a problem.
Installed roofing filters are 2.8, 1.8, 1.0, 40
Perhaps someone can clarify / correct my use of the per-band quick memories.
I'm using M1 to M4 to save sub-band frequencies and filter positions with BW
settings in each of the bands 160 thru 10 and having a problem.
Installed roofing filters are 2.8, 1.8, 1.0, 400 & 250. Firmwa