Re: [Elecraft] K2 - Bar Graph Erratic - New symptoms

2019-05-05 Thread Robie Elms
This problem has been resolved. I was able to identify a poor solder joint on the bar graph IC. Reflowing the joint solved the problem. 73, Robie - AJ4F On Sat, Apr 27, 2019 at 8:57 PM Robie Elms wrote: > I posted several days ago about the bar graph (s meter & w meter) on my K2 > was

[Elecraft] K2 - Bar Graph Erratic - New symptoms

2019-04-27 Thread Robie Elms
I posted several days ago about the bar graph (s meter & w meter) on my K2 was erratic. I received suggestions suggesting changing the RF gain control and re-doing the S meter calibration. Today i did the following: 1. carefully monitored the audio from K2 as the RF gain control was rotated and

Re: [Elecraft] K2 - Bar Graph Erratic

2019-04-21 Thread Don Wilhelm
Robbie, It sounds to me like you have an RF Gain Control that is worn. Sine it has been out of service for a while, you might be able to restore it by rotating the RF Gain knob through its rotation 10 to 20 times. If that does not correct it, then replacing the control is the only option.

[Elecraft] K2 - Bar Graph Erratic

2019-04-21 Thread Robie Elms
All, My K2 has been out of service for an extended period. Today, I put it back on the air and it appears to function properly, except for the bar graph display which is erratic. When I rotate the rf gain control counter clockwise segments begin to illuminate until the 3rd is illuminated. As i