>> Brett,
>>
>> Check the components in the 15/17 m Low Pass Fil
: "Don Wilhelm"
To: "Brett Gazdzinski"
Cc:
Sent: Thursday, January 22, 2009 1:01 AM
Subject: Re: [Elecraft] K2 high current on 15 meters
> Brett,
>
> Check the components in the 15/17 m Low Pass Filter carefully. Examine
> C218, C219, C220, C221 and C222 for
Brett,
Check the components in the 15/17 m Low Pass Filter carefully. Examine
C218, C219, C220, C221 and C222 for correct values. Then count the
number of turns on L23 and L24. Count the number of times the wire
passes through the center of the core rather than the turns around the
outside.
I built K2 #6673 last week, and everything works well, except for a high
current warning on 15 meters. The current is set at 3 amps.
Things seem fine up to about 10 watts, above that, the current goes up and
the power out stays the same.
In doing the initial receiver alignment, 15 and 17 meters
4 matches