Re: RE: [Elecraft] K2 Alignment Test, Part II PLL problem, Continued

2006-04-19 Thread rootboy
], elecraft@mailman.qth.net Subject: RE: [Elecraft] K2 Alignment Test, Part II PLL problem, Continued John, For the time being (until you solve the current problem) the only voltages at U6 that matter are pins 1, 2 and 3 - and those are correct. The other pins will likely fall into line after you

Re: RE: [Elecraft] K2 Alignment Test, Part II PLL problem, Continued

2006-04-19 Thread rootboy
is that the list of original parts left to be replaced is dwindling. :) Thanks again for all the help, John From: k4zm [EMAIL PROTECTED] Date: 2006/04/19 Wed AM 07:26:45 CDT To: [EMAIL PROTECTED] Subject: Re: RE: [Elecraft] K2 Alignment Test, Part II PLL problem, Continued John: The other

RE: [Elecraft] K2 Alignment Test, Part II PLL problem, Continued

2006-04-08 Thread Don Wilhelm
Be certain you have correctly installed L31 and that it is the 10 uH shielded inductor. Resistor R115 is about the same size - is there a possibility that you exchanged these parts? Be certain you have D16, D17 and D18 inserted the proper way around (the Parts Placement Diagram is handy for