How did you determine that the cables seem "fine".
Did you do a continuity measurement on each pin? Did you check for
shorts between adjacent pins.
If selecting 12 meters on the K3 produces 6 meters on the KPA500, then
there may be something awry with the BAND1 data output from the K3 to
the
Solved. It was one of the cables. Anyway I believe so. I took the KAT out of
the control loop and all is well with one of the cables but bad news with the
other. Must be intermittent as it ohm 'd ok.
Sent from my iPhone
> On Aug 3, 2016, at 8:05 PM, Harlan Sherriff wrote:
>
> Tom
> They both
Both cables seem ok. Also, if I select 12m on K3, the KPA goes to 6m. I'm just
a little confused.
Sent from my iPhone
> On Aug 3, 2016, at 8:05 PM, Harlan Sherriff wrote:
>
> Tom
> They both seem fine.
>
> Sent from my iPhone
>
>> On Aug 3, 2016, at 5:50 PM, tomb18 wrote:
>>
>> Hi
>> Che
Tom
They both seem fine.
Sent from my iPhone
> On Aug 3, 2016, at 5:50 PM, tomb18 wrote:
>
> Hi
> Check your 15 pin cable.
> 73 Tom
> va2fsq.com
>
>
>
> Sent from my Samsung Galaxy smartphone.
>
> Original message
> From: Harlan Sherriff
> Date: 2016-08-03 5:43 PM (GMT
HiCheck your 15 pin cable.73 Tom va2fsq.com
Sent from my Samsung Galaxy smartphone.
Original message From: Harlan Sherriff
Date: 2016-08-03 5:43 PM (GMT-05:00) To: Elecraft Email
Subject: [Elecraft] KPA500 strange response
No matter how I change bands (k3, KPA front panel