Screen Room

1996-05-16 Thread rbusche
Evans & Sutherland is selling an old copper screen room. It is approximately 10 foot by 16 foot by 8 foot. The room is comprized of 40" copper screen panels so the room size could be altered. It is complete with the line filters, 36 " door, internal lights, bench and power outlets. We need to move

EMI testing in a noisy environment

1996-05-16 Thread Moshe Valdman
Hi everybody, I am sure many of you encountered the situation of trying to perform EMI measurements with a spectrum analyzer or receiver in an environment where "environmental" signals have very close frequencies to the ones you are trying to measure. This could so

Re: Environmental Seminars??

1996-05-16 Thread Eric Petitpierre
Craig, American European Services 1054 31st Street, N.W. #120 Washington D.C. 20007 USA (tel) 202-337-3214 (fax) 202-337-3709 Mr. Eric Thibau Mr. Bill Coles or TUV Rheinland of North America, Inc. North Ameri

RE: EMI testing in a noisy environment

1996-05-16 Thread Tony Fredriksson
Hi Moshe, 100 Hz apart is awfully close to separate the signals. I do a lot of my precompliance testing using a spectrum analyzer, FET probe, current probe, and H-Field/E-Field near field probes. With some experience, it is possible to get "ballpark" ideas as to whether or not the equipment has

FCC report and order of Docket 95-19 FCC 96-208 Release May 14 1996.

1996-05-16 Thread Leo . Heiland
The entire Report and Order is on the Internet at the following adress: http://www.fcc.gov/bureaus/engineering_technology/orders/fcc96208.txt Get your own copy ] Leo Heiland SCI Systems Inc. Huntsville, AL 205-882-4743 205-882-4305 Fax

Environmental Seminars??

1996-05-16 Thread CRAIG HENSLEY
I am looking for information or recommendations on seminars/classes which deal with current and future product environmental compliance issues, (i.e., recycle markings, packaging, material usage). I believe these issues are going to be increasingly important (especially in Europe), and would like