Re: FW: ERO Newsflash No 30

2002-02-14 Thread John Woodgate
I read in !emc-pstc that Leslie Bai wrote (in <20020214191203.56528.qm...@web10908.mail.yahoo.com>) about 'FW: ERO Newsflash No 30', on Thu, 14 Feb 2002: >I am wondering why EN 301 893 (BRAN HIPERLAN TYPE 2, Harmonized EN >covering essential requirements of article 3.2 of the R&TTE >

Re: Existing EN50082-1 approved products

2002-02-14 Thread John Woodgate
I read in !emc-pstc that douglas_beckw...@mitel.com wrote (in <85256b60.0068f0e2...@kanmta01.software.mitel.com>) about 'Existing EN50082-1 approved products', on Thu, 14 Feb 2002: >So far everyone has supported >my position, that re-test is required and a declaration to EN50082-1 is no >longer va

Re: LVD - Test lab in EU

2002-02-14 Thread Kevin Keegan
Try KTL in the U.K. Regards Kevin Keegan KES & Associates - Original Message - From: To: Sent: Thursday, February 14, 2002 1:20 PM Subject: LVD - Test lab in EU > > Hi all, > > We are searching for a test lab in Europe, which can carry out electrical > safety tests on a Residual curr

RE: [URGENT] Need some information about NEBS..

2002-02-14 Thread Gregg Kervill
My experience is much the same - USE A STRUCTURED APPROACH - Identify the Need - plan to Do what is Necessary for your product - CONFIRM THE NEED before commitment. Best regards Gregg PLEASE NOTE: We are currently experiencing serious problems with our service provider PLEASE reply only to g

RE: Creating a Reliability Department

2002-02-14 Thread Matt Kilkenny
>3) Reliability in manufacturing would not constitute a conflict of interest >as compliance could. Compliance is more like an unbiased judge where >Reliability provides input to improve products to make them more robust. I respectfully disagree with Paul. While I'm sure there are some reliability

Re: FW: ERO Newsflash No 30

2002-02-14 Thread Leslie Bai
Rich and all interested members: I am wondering why EN 301 893 (BRAN HIPERLAN TYPE 2, Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive) was not listed as specific standards (REC 70-03, Page 11), and only ETS 300 836-1 (HIPERLAN TYPE 1) was there. Also, on Page

Re: Existing EN50082-1 approved products

2002-02-14 Thread Douglas_Beckwith
From: Douglas Beckwith@MITEL on 02/14/2002 02:06 PM Hi All, Thanks for the response. I just want to clarify that this is not our product, it was prompted by a discussion I had with a someone. So far everyone has supported my position, that re-test is required and a declaration to EN50082-1 is n

RE: Existing EN50082-1 approved products

2002-02-14 Thread Binnom, Cyril A
Douglas, EN 55024:1998 only supercedes EN 50082-1 if your product is by definition ITE equipment. Assuming your product is ITE, if you intend to sell that product after the date of withdrawl 2001-07-01, the product has to comply with EN 55024 and this has to be noted on a new DoC. Cyril A. Bin

FW: Creating a Reliability Department

2002-02-14 Thread Darrell Locke
Forwarding for Paul Darrell Locke -Original Message- From: Paul Paroff Sent: Thursday, February 14, 2002 7:44 AM To: Darrell Locke Subject: RE: Creating a Reliability Department 1) From the Manufacturing side I would study warranty and other returns, customer complaints, and field ser

RE: [URGENT] Need some information about NEBS..

2002-02-14 Thread Robert Wilson
Without getting into details, the main point is that it is brutal (and even that is an understatement), and it is expensive. A full-on test involves everything from EMI compliance, to earthquake testing, to flame and fire tests. Costs can easily run to US$100,000 and time to do the test can range f

USB Interface and Cables

2002-02-14 Thread brian_kunde
Greetings, We have an analyzer that is controlled by a standard PC through the USB interface. When performing Fast Transient Burst test on the analyzer (according to EN61000-4-4 Level 3) at 2KV the USB communications goes down and does not recover without re-powering up the unit. We found that t

LVD - Test lab in EU

2002-02-14 Thread amund
Hi all, We are searching for a test lab in Europe, which can carry out electrical safety tests on a Residual current monitor (earth fault detector). We assume that electrical safety on this unit is covered by the harmonized LVD standard EN62020:1998/IEC62020:1998 Electrical accessories - Residua

THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIB ILITY (EMC), Tel Aviv, ISRAEL, May 11-16, 2003

2002-02-14 Thread Jim Bacher
Forwarding for Nicky. -Original Message- From: Nicky Jowett Sent: Thursday, February 14, 2002 8:06 AM Subject: THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIB ILITY (EMC), Tel Aviv, ISRAEL, May 11-16, 2003 THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMP

Re: Existing EN50082-1 approved products

2002-02-14 Thread Ron Pickard
Doug, After July 1, 2001, EN50082-1:(1992 or 1997) no longer gives a presumption of conformity for ITE to the EMC Directive. This is, of course, assuming your product is ITE, then EN55024 must indeed apply. Your declaration of conformity also needs to be updated to reflect this. If your produ

RE: Existing EN50082-1 approved products

2002-02-14 Thread richwoods
If you choose to apply standards, then each of every unit placed on the market or into distribution after the DOW of 2001-07-01 must comply with EN55024 and this must be stated on a new DoC. Re-testing is only required if a requirement of the new standard differs from the old standard and the requ

Re: INNOVA Product Service GmbH

2002-02-14 Thread Anthony Villasenor
Brian, The person to contact would be Horst Haug, email address: innova...@t-online.de Anthony From: "MCA Compliance" To: "Emc-Pstc Post" Subject:INNOVA Product Service GmbH Date sent: Thu, 14 Feb 2002 15:58:27 - Send r

Re: [URGENT] Need some information about NEBS..

2002-02-14 Thread Cortland Richmond
This message had no text in its body. This is because you sent it in an attachment. To read what you wrote, we who use off-line-readers on Compuserve are required to locate and edit the downloaded file that actually contains your message. This would not happen if you placed text in the message bod

Re: Existing EN50082-1 approved products

2002-02-14 Thread JRadomski
Doug, > EN55024 came into effect on July 1, 2001, and superceded EN50082-1. If a product was legally being sold in the EU, before that date, and was compliant to EN50082-1, does the product need to be re-tested to EN55024 to be sold after that date, YES, to EN55024. > if there are no changes t

INNOVA Product Service GmbH

2002-02-14 Thread MCA Compliance
Can anyone provide information on this test lab ? Are they part of TUV group ?? contact details thanks Brian McAuliffe email: i...@mcac.ie --- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. V

Fw: EMC Cost Benefit Analysis Report

2002-02-14 Thread Alan E Hutley
Hi All I apologise for confusion the link for the Cost Benefit Analysis was pasted in wrong message. Sorry. Alan http://europa.eu.int/comm/enterprise/electr_equipment/engin/cba.pdf - Original Message - From: Alan E Hutley To: Emc-Pstc Discussion Group Sent: Thursday, February 14, 2002

FW: ERO Newsflash No 30

2002-02-14 Thread richwoods
-Original Message- From: Pia Hammer Bloch [mailto:bl...@ero.dk] Sent: Thursday, February 14, 2002 9:07 AM To: ERO-NEWS Subject: ERO Newsflash No 30 ERO NEWSFLASH No 30 14 February 2002 -- Recommendation 70-03 updated The Sh

RE: [URGENT] Need some information about NEBS..

2002-02-14 Thread Mike Cantwell
NEBS compliance is required by the US Regional Bell Operating Companies (RBOCs). The major aspect of this consist of Telcordia standards ( www.telcordia.com ): GR-1089-CORE:EMC and safety GR-63-CORE:Environmental If you have products that must comply with

Existing EN50082-1 approved products

2002-02-14 Thread Douglas_Beckwith
Hi All, As we all know, I hope, EN55024 came into effect on July 1, 2001, and superceded EN50082-1. If a product was legally being sold in the EU, before that date, and was compliant to EN50082-1, does the product need to be re-tested to EN55024 to be sold after that date, if there are no changes

A Report: EMC in European Electricity suppl Networks

2002-02-14 Thread Alan E Hutley
Hi All A summary of a report soon to be issued has been released by EURELECTRIC the Union of the Electricity Industry. on trends in harmonic distortion. This is in response to intensive lobbying activities by the US IT manufacturers and their representatives in the EU, it says in the summary.

Fw: A Report: EMC in European Electricity suppl Networks

2002-02-14 Thread Alan E Hutley
Oops forgot to add link http://europa.eu.int/comm/enterprise/electr_equipment/engin/cba.pdf - Original Message - From: Alan E Hutley To: Emc-Pstc Discussion Group Sent: Thursday, February 14, 2002 10:26 AM Subject: A Report: EMC in European Electricity suppl Networks Hi All A summar

RE: [URGENT] Need some information about NEBS..

2002-02-14 Thread Peter Merguerian
Michelle, I am forwarding your e-mail to our NEBS expert, Ilan Cohen, for help. For your info, we are also holding a NEBS seminar March 18 and 19th here in Israel with speakers from the USA. You are most welcome to attend. This e-mail message may contain privileged or confidential information.

EMC Cost Benefit Analysis Report

2002-02-14 Thread Alan E Hutley
Hi Group The above report(197 pages). Full title " Cost Benefit Analysis on the Draft Amendment of the EC Directive on Electromagnetic Compatibility " prepared for the Directorate-General Enterprise of the EU. Can be found here in pdf format. Enjoy Cheers Alan E Hutley EMC Compliance Journal

Need a screened room?

2002-02-14 Thread Schaefer, Rolf
Restructuring and move to another location has caused that a screened room is available immediately, its size is 5240 x 4150 x 2220 mm. It is still installed near Frankfurt/Main. If you are interested contact our facility manager directly (Ulf Wittich: email ulf.witt...@de.unisys.com - tel +49

[URGENT] Need some information about NEBS..

2002-02-14 Thread Michelle Cho / INT Compliance
Dear all, I need some help about something called NEBS(Network Equipment Building System). The whole procedure... What exactly the NEBS is and where can I do the testing? How much? How long does it take? Thanks in advance! Michelle

Re: Flammabilty requirement for cloth used on loudspeaker / UL6500

2002-02-14 Thread John Woodgate
I read in !emc-pstc that Peter Tarver wrote (in ) about 'Flammabilty requirement for cloth used on loudspeaker / UL6500', on Wed, 13 Feb 2002: >My note on the outside says >"hexamethylene tetramine C16H12N4," that last bit being the >precise chemical composition. Not precisely! It's C6H12N4, or,

3H AC Source

2002-02-14 Thread Brian O'Connell
Good People My AC source just died. Manual & schematics we have are not for this particular model (3H Industries Model 3001). Does anyone have a manual that I can buy or pay for a copy??? My safety testing is on hold until I can fix this 15 year-old beast. much thanks, Brian O'Connell Taiyo Yud

Re: Creating a Reliability Department

2002-02-14 Thread Doug McKean
> I have been given a consulting opportunity to develop a plan for a > Reliability Department for a fairly large manufacturing company of > Laboratory Equipment. > > Since my background is in compliance I could use some advice on how to get > started. > > 1. The goal is to hire one permanent emp

Re: Flammability requirement for cloth used on loudspeaker / UL6500

2002-02-14 Thread JRadomski
Hi Pierre, Here is my suggestion: request this information from the manufacturer (I doubt you will get it), buy the tablets and conduct this test in your own lab. Regards, John Radomski Clare