George said:
>In the ideal world, there will be one global mark to indicate that the
>product meets all safety, health, EMC, environmental, and other applicable
>standards. The CE mark is virtually this ideal mark, but is only accepted
>within the 15 member states of the European Union and a fe
of prefixes
!
Roger
Gary McInturff on 06/01/2000 22:49:38
Please respond to Gary McInturff
To: "'Egon H. Varju'" , EMC-PSTC
cc: (bcc: Roger Viles/PLY/Global)
Subject: RE: Y3K
Oh my last birthday my children wanted to know if I was really, really sad
whe
Personally I'm still waiting for another 48 years until the Y2K bug bites!
Aside from its real meaning as degrees Kelvin, capital K was first used by the
computer guys as a de-facto agreed unit for binary thousand (1024) as in Kbytes.
Sloppiness by the financial community led to its use there f
The general rule requires that "CE marking must be affixed to the product or its
data plate. However where this is not possible or not warranted on account of
the nature of the product, it must be afixed to the packaging, if any, and to
the accompanying documents, where the directive concerned p
Apart from what is in EN/IEC 60825-1, are there any health and safety
regulations or guidelines for the safety of employees in UK/Europe assembling
and testing products containing certified laser modules? Can anyone point me to
helpful information on this topic?
Happy Xmas and bug-free Year 20
To: emc-p...@ieee.org
cc:(bcc: Roger Viles/PLY/Global)
Subject: EN60204-1:1998 Title Published in the OJ Yet?
Hey folks --
Can anyone tell me if EN 60204-1:1998 has been published in the OJ yet in
conjunction with the Machinery Directive?
(I've got copies of EN 60204-1:1992 an
uhasz
To: "'emc-p...@majordomo.ieee.org'"
cc:(bcc: Roger Viles/PLY/Global)
Subject: Marketing/Offering for Sale in Europe
I need some clarification regarding marketing of equipment . . .
In the US we cannot market/advertise (or offer for sale) a product which has
on 05/12/99 22:07:09
Please respond to Frank West
To: Robert Macy , Antonio Sarolic
, emc-p...@majordomo.ieee.org
cc: Antonio (bcc: Roger Viles/PLY/Global)
Subject: Re: warning label overkill?
Perhaps the Europeans will soon draft a new directive
for the safety of these
See also a report on a double-blind study carried out in Bristol, UK:
http://www.bris.ac.uk/Depts/Info-Office/news/archive/phone.htm
Some effects were observed but the author Dr Alan Preece cannot confirm any
damage is caused. However he told me that he only ever uses his own mobile phone
for a
uk"
, "Smith Martin(PBD" ,
"John Warren(QA" , "'BSI: White Ken'"
, "Spicer Keith(QA" (bcc:
Roger Viles/PLY/Global)
Subject: R&TTE Directive - Transitional periods
Hi folks
I have just been sent a cop
To: "'Ing. Gert Gremmen'" , Rich Nute
cc: Emc-Pstc (bcc: Roger Viles/PLY/Global)
Subject: RE: UL in Washington Post
I also agree with Rich that independent accredited test organizations only
verify conformance to standards. A few of those standards are performance
b
I read Sandy's question to refer to ancillary equipment sold as part of a
system, rather than "incorporated into a device". Where the EMC performance of
the combined system has been shown to meet the requirements, then it is not
necessary for each individual item to be C-Tick marked, providing t
There is a further issue because the generic emissions standard EN 50081-1
covers the "Residential, Commercial and Light Industrial" environment, i.e. the
only one it does not cover is the real industrial (EN 50081-2). This means that
all normal commercial applications require EN 50081-1 which s
Not a recommendation - I just saw the ad in Compliance Engineering - but
non-combustible pyramid absorbers are offered by the German company Frankonia.
See: www.frankonia-emc.com
Roger
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail
(bcc: Roger Viles/PLY/Global)
Subject: 2B1Q Vs 4B3T Layer one line coding
To All:
I have ISDB with Basic Rate Interface Line codig (2B1Q) for USA use. How
this will be compatible with European line coding standard
(4B3T). My interface is U interface.
Regards
Nezam Najafi
Compliance Engineer
I agree this is a good question, and have been following this with interest to
see what crops up. One point worth making is that the DoC signatory is legally
responsible under criminal law. Signing a DoC fraudulently claiming compliance
is a criminal offence and such criminal liability cannot be
to Rick Loiselle
To: emc-p...@majordomo.ieee.org
cc:(bcc: Roger Viles/PLY/Global)
Subject: Packaging material
Hello,
Has anyone heard of EPS (polystyrene?) packaging material soon to be "not
accepted" in the European Community because it is a Non-recycling material?
Be
I have the same information from Approval magazine (www.approval.co.uk). Editor
Adrian MacLeod says that lobbying from US companies and those who trade with
North America has led to this further extension to 31 Dec 2009. The EC wants the
US to allow only the use of SI units, but it seems that Eu
directly
as the harmonised standard by which you declare your product compliant with the
emissions aspects of the EMC Directive? Then you can use any applicable category
from that standard.
Roger
"Brian At Work" on 30/09/99 14:26:52
Please respond to "Brian At Work"
To: "I
and so resistance in
any of the leads has no effect on the measurement.
Sorry if this is too obvious - but sometimes we all forget the KISS solution!
Roger
Derek Walton on 24/09/99 16:44:36
Please respond to Derek Walton
To: IEEE EMC Discussion Group
cc: (bcc: Roger Viles/PLY/Global
.
You should contact IRAM concerning this: try Osvaldo Petroni there on e-mail:
irame...@sminter.com.ar
Roger Viles
WWG
fi...@panametrics.com (Paul Finn) on 20/09/99 16:12:08
Please respond to fi...@panametrics.com (Paul Finn)
To: emc-p...@ieee.org
cc:(bcc: Roger Viles/PLY/Global)
Su
e of the most useful web pages for anyone concerned with CE Mark
issues!
Roger Viles
WWG
marti...@pebio.com on 17/09/99 21:27:08
Please respond to marti...@pebio.com
To: emc-p...@majordomo.ieee.org
cc:(bcc: Roger Viles/PLY/Global)
Subject: "Kill" Switch Requirements
es, and if you have the dynamic range, add more attenuation. This will
guard against both mismatch problems and receiver spurious problems caused by
non-linearities.
Hope this helps,
Roger Viles,
WWG
Otherwise
Jim Eichner on 15/09/99 23:52:52
Please respond to Jim Eichner
To: "
Martin,
Immunity requirements are not (yet) mandatory in Australia. See
http://www.aca.gov.au/standards/emcbook/index.htm which will tell you all about
their C-Tick requirements
Roger Viles
WWG
mart...@panametrics.com (Charles Martin) on 14/09/99 22:17:37
Please respond to mart
George is correct - TBR 21 is available free from ETSI but you won't find it if
you search Publications Download for TBR 21.
You have to look for TBR 021!
To short cut the search go to http://webapp.etsi.org/publicationstemp/2914.htm
Roger Viles
WWG
-
This message is coming
approvals Notified Body (or, outside Europe, a lab
with a suitable MRA).
Roger Viles
WWG
"john Chan" on 08/09/99 19:26:12
Please respond to "john Chan"
To: emc-p...@majordomo.ieee.org
cc: (bcc: Roger Viles/PLY/Global)
Subject: CTR
Hi,
Currently, I am
25 E1
Service Tester (see http://www.wg.com/products/est125/est125.html)
Roger Viles
WWG
Dwight Hunnicutt on 07/09/99 18:52:45
Please respond to Dwight Hunnicutt
To: EMC PSTC , TREG Newsgroup
cc:(bcc: Roger Viles/PLY/Global)
Subject: E1 performance spec
Is there a spec that i
ding
Competent Bodies, Notified Bodies, RECAB
on topics such as:
EMC, Safety, Radio, Medical devices and machinery and new &End
of
Life8 Environmental Legislation
Free buffet lunch available from 13:00 onwards.
Hope to see some of you there!
Roger V
cket calculator covered? Surely not."
So I too would like a definitive answer! (Well, if the answer is definitive, it
probably comes from a lawyer, so I might not like it!).
Regards,
Roger Viles
WWG
Doug McKean on 17/08/99 04:48:09
Please respond to Doug McKean
To: emc-p...@majordo
ond to "Davis, Mike"
To: "Davis, Mike" , "'EMC-PSTC Regulatory E-Mail
(E-mail)'"
cc:(bcc: Roger Viles/PLY/Global)
Subject: RE: Posters
Ask and you shall receive!.. Seek and you shall find!.. EMC-PSTC has again been
fruitful! Please Co
Useful info on ISO 9000-2000, though not the actual draft standard, is
available from BSI:
http://www.bsi.org.uk/iso-tc176-sc2/executive.htm
The home page of the responsible technical committee in ISO is at:
http://www.bsi.org.uk/iso-tc176-sc2/
Roger Viles
WWG
Nezam Najafi on 13/08/99
ales.bra...@wwgsolutions.com
See EMF testers at: http://www.wg.com/products/emf/en/emf_en.html and WWG's
Brasil website in Portuguese at: http://brasil.wg.com/
Roger Viles
WWG
Muriel Bittencourt de Liz on 13/08/99 15:53:43
Please respond to Muriel Bittencourt de Liz
To: Lista de EM
attenuation of your
factory walls (in case of emissions).
In practice it is the safety of your employees which is the critical issue
unless you build rf transmitters in your boxes!
Roger Viles
WWG
carlos.perk...@eu.effem.com on 13/08/99 07:22:17
Please respond to carlos.perk...@eu.effem.com
, cadmium, etc by 1 Jan 2004. This includes a ban on lead solder!
You can get the draft directive, and read the American Electronics Association
(AEA)'s position on it, at:
http://www.svtc.org/cleancc/weeeaea.htm
Roger Viles
WWG
"Brian Harlowe" on 05/08/99 17:18:40
Please respond to
UK EMC Journal
reports (http://www.emc-journal.co.uk/archive1/980402.html) , it is now run by
Celestica.
Roger Viles
WWG
"Lacey,Scott" on 04/08/99 16:37:09
Please respond to "Lacey,Scott"
To: "'Price, Ed'"
cc: "'emc-p...@ieee.org
o not require it to be marked anywhere else on the
product.
Roger Viles
WWG
Nick Williams on 03/08/99 22:13:34
Please respond to Nick Williams
To: Chuck Seyboldt , EMC-PSTC Discussion Group
cc:(bcc: Roger Viles/PLY/Global)
Subject: Re: The meaning of "Affixed"
a/mrr/mark0001.html
and
http://www.icc-uk.com/News.htm#ARG002 1 July 1999
Hope this helps,
Roger Viles
Group Standards Manager
Wavetek Wandel Goltermann
"Barry Esmore" on 03/08/99 06:58:39
Please respond to "Barry Esmore"
To: "EMC-PSTC"
cc:(bcc: Roger
ntact info useful.
Roger Viles
Group Standards Manager
Wavetek Wandel Goltermann
"Biggs, Daniel (IndSys, GEFanuc, NA)" on 02/08/99
19:37:42
Please respond to "Biggs, Daniel (IndSys, GEFanuc, NA)"
To: "'EMC forum'"
cc:(bcc: Roger Viles/PLY
http://www.relexsoftware.com/
The complete SW package from Relex costs about $10k including the database
Bellcore is more suited to commercial products.
Siemens Germany also have a SW package called EXAR costing DM6500 but I have no
contact info.
Roger Viles
Group Standards Manager
Wavetek Wandel Golte
: Tue 14 September 1999
TIME: 10 am till 4 pm
VENUE:University of Exeter, Devon, UK
CONTACT: Exeter Enterprises Ltd., tel: 01392 214085, e-mail:
enterpri...@ex.ac.uk
TRAVEL: See: http://www.ex.ac.uk/public_html/EXETER_DIRECTIONS.html
I hope to see some of you there!
Roger Viles
Group
technical documentation referred to in point 2 and with the
requirements of this Directive that apply to them.'
All "New Approach" Directives are available from the EU server at:
http://europa.eu.int/comm/dg03/directs/dg3b/newapproa/eurstd/harmstds/reflist.html
Just click on the Directive
French Customs law which we were
referred to deals only with EMC and not with the LVD.
Roger Viles
Group Standards Manager
Wavetek Wandel Goltermann
RCIC - http://www.rcic.com
Regulatory Compliance Information Center
-
This message is coming from the emc-pstc discussion list.
To
ny EU laws?
Thanks for any help,
Roger Viles
Group Standards Manager
Wavetek Wandel Goltermann
-
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to majord...@ieee.org
with the single line: "unsubscribe emc-pstc" (without the
quot
43 matches
Mail list logo