securely with nylon tie wrap.
Product should not be accessible when mains are powered without adequate PPE.
Chris
From: John Woodgate
Sent: Saturday, October 26, 2019 4:11 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Re: [PSES] Terminal block pitch pcb creepage/clearance 400VL:N/G;
600/690
If you have room for the 7-position block, go for it to save a lot of
argument about other 'solutions'.
Best wishes
John Woodgate OOO-Own Opinions Only
J M Woodgate and Associates www.woodjohn.uk
Rayleigh, Essex UK
On 2019-10-26 20:36, Chris Wells wrote:
I want to monitor mains of polyphase p
I want to monitor mains of polyphase power systems VA/VB/VC/VN using EN/UL
61010-1
Ratings: 400VL:N/G; 600/690 L:L CAT III, PD2, 3Km elevation
Issue I see is to get the phase to phase spacings on my terminal block.
Requirements in Annex K are 5.5mm at 2Km but go up to ~ 6.3mm at 3Km.
I woul