Hygroscopic Dust Troubleshooting

2000-09-18 Thread Kretsch, John
I thought I would try to contact the collective on this one... We have a shelf system that is failing GR-63 hygro dust with excessive bit errors (unit did pass Gaseous contaminants no problem). Air is filtered. Anyone have experiences that they would like to share (non-proprietary of course) abou

RE: Hygroscopic Dust Troubleshooting

2000-09-18 Thread Tudor, Allen
has been done about it. -Original Message- From: Kretsch, John Sent: Monday, September 18, 2000 11:06 AM To: 'n...@world.std.com'; 'EMC PSTC'; 'TREG Newsgroup' Subject: Hygroscopic Dust Troubleshooting I thought I would try to contact the collective on this

RE: Hygroscopic Dust Troubleshooting

2000-09-18 Thread Marko Radojicic
nt: Monday, September 18, 2000 8:06 AM To: 'n...@world.std.com'; 'EMC PSTC'; 'TREG Newsgroup' Subject: Hygroscopic Dust Troubleshooting I thought I would try to contact the collective on this one... We have a shelf system that is failing GR-63 hygro dust with exc