Re: Class I or II UK Wall plu power supplies

2007-02-16 Thread emc-p...@ieee.org
In message <1f5308c5923f3b4daa51d189bf25500601eea...@edgmsmail01.eu.thmulti.com>, dated Fri, 16 Feb 2007, Carpentier Kristiaan writes: >If the PSU design is the same but there is a metal earth pin that >is not connected inside the adaptor, can the Class II marking still be >affixed? Yes. Th

RE: Class I or II UK Wall plu power supplies

2007-02-16 Thread emc-p...@ieee.org
I do not know what the view of an approvals body such as ASTA might be, but I can see no technical reason provided that the insulation requirements between the live parts and the metal pin are met and can be assured. I am sure that the use of a plastic pin is both to simplify the design and to redu