Re: Siganl transformer requirements for Australia

1996-11-19 Thread bwrigley
Jim Generally basic insulation (1.5mm creepage, 1.0mm clearance) is required between TNV circuitry (AUSTEL still class ISDN as TNV) and SELV circuitry, in accordance with AS/NZS3260 clause 6.2.1.2. Additionally AS/NZS3260 clause 6.3.3 requires supplementary insulation (2.5mm creepage, 2.0mm

Re: Siganl transformer requirements for Australia

1996-11-19 Thread Kevin Richardson
Jim Wiesse wrote: Does anyone know the requirements for signal transformers for ISDN S/T interfaces in Australia. I do not have a copy of AS/NZS 3260 at this time. Specifically, I need to know the creepage, clearance, and insulation category requirements for the S/T interface and S/T

Siganl transformer requirements for Australia

1996-11-18 Thread Jim Wiese
Does anyone know the requirements for signal transformers for ISDN S/T interfaces in Australia. I do not have a copy of AS/NZS 3260 at this time. Specifically, I need to know the creepage, clearance, and insulation category requirements for the S/T interface and S/T interface circuits in