McInturff
Sent: Monday, February 12, 2001 11:29 AM
To: EMC-PSTC (E-mail)
Subject: Surge to 4Kv
The last information I have is that EN55024:1998, which becomes
effective very soon still only identifies surge test of 2Kv line to
ground,
but I have a persistant buzzing
ETS 300 386-2 requires a performance criteria R surge of 4kv Line-Ground
for other than telecommuncations centres, ac power ports (Section
5.2.4.8). Keep in mind this standard only applies to Telecommunication
Network Equipment, so depending on what you make, this may be
irrelevant.
Dave Heald
The last information I have is that EN55024:1998, which becomes
effective very soon still only identifies surge test of 2Kv line to ground,
but I have a persistant buzzing in my ear from a single source that is
claiming it actually requires 4Kv for the surge test.
Has anyone else
3 matches