2001-02-19 Thread Wagner, John P (John)
McInturff Sent: Monday, February 12, 2001 11:29 AM To: EMC-PSTC (E-mail) Subject: Surge to 4Kv The last information I have is that EN55024:1998, which becomes effective very soon still only identifies surge test of 2Kv line to ground, but I have a persistant buzzing

Re: Surge to 4Kv

2001-02-13 Thread daveheald
ETS 300 386-2 requires a performance criteria R surge of 4kv Line-Ground for other than telecommuncations centres, ac power ports (Section 5.2.4.8). Keep in mind this standard only applies to Telecommunication Network Equipment, so depending on what you make, this may be irrelevant. Dave Heald

Surge to 4Kv

2001-02-12 Thread Gary McInturff
The last information I have is that EN55024:1998, which becomes effective very soon still only identifies surge test of 2Kv line to ground, but I have a persistant buzzing in my ear from a single source that is claiming it actually requires 4Kv for the surge test. Has anyone else