Am 15.01.2010 00:34, schrieb Andy Pugh:
2010/1/14 Sebastian Reinhardts...@lmv-hartmannsdorf.de:
I get no error or messages, so I do not know where I can start searching
for an error.Please help me to get EMC working!
Running EMC2 on a SMP kernel is something of an enthusiasts
The first rule of sending a screenshot is: simply don't. Better
to use lspci somefile then use network or sneakernet to get it to
where you're doing e-mail. Second best option is to transcribe it.
If you simply can't get by without an image, remember that you can
*resize* the image (change the
Dear Sebastian
I get no error or messages, so I do not know where
I can start searching
for an error.Please help me to get EMC
working!
Running EMC2 on a SMP kernel is something of an
enthusiasts choice. Do
you have a good reason not to run EMC on the default
Live-CD
On Friday 15 January 2010, Jeff Epler wrote:
The first rule of sending a screenshot is: simply don't. Better
to use lspci somefile then use network or sneakernet to get it to
where you're doing e-mail.
My local floppy is busted. And I don't know about the one in that machine,
never used it. I
Found the the root of the problem I described last week. I was using X11
forwarding to communicate between my pc and the EMC2 host machine. I figured
this was a way to reduce the number of monitors/mice I had to have cluttering
up my work area. For some reason that is what broke EMC2. After
Neil Baylis wrote:
OK, so I started up the computer, then waited 1/2 hour. Then I ran the
latency test for 1/2 hour with no abuse, and the latency was below 7
microseconds. I have plenty of other computers, so I certainly don't
need to be doing anything else on my EMC box when it's running
I'm working in a piece of .hal to control a VFD-spindle
It is no working. I miss something??
The spindle needs : 0-10V (positive)to control, and enable, forward,
reverse signals
ArnoldRiter
#SPINDLE
newsig SpindleFwd bit
net SpindleFwd = motion.spindle-forward
setp
Kasey Matejcek wrote:
I want to setup home using the index pulse from the encoder
I have Pico system servo controller version 2 running current firmware and
the current version of EMC
I must be missing something in hal that need to be turn on looked through
the examples
I even hooked up
Flying Electron wrote:
I think you want to connect the signal coming from the index to the
axis.N.home-sw-in of the axis you want to home.
net axis0homeswitch ppmc.0.din.03 = axis.0.home-sw-in
then try setting the index-enable to true
setp axis.0.index-enable TRUE
The way this
Am 15.01.2010 16:43, schrieb Chris Epicier:
Dear Sebastian
I get no error or messages, so I do not know where
I can start searching
for an error.Please help me to get EMC
working!
Running EMC2 on a SMP kernel is something of an
2010/1/15 Arnoldritercnc arnoldriter...@gmail.com:
I'm working in a piece of .hal to control a VFD-spindle
It is no working. I miss something??
I think you might have missed the PWM-enable signal.
Do you need the inverts? What hardware is there between the direction
pins and the VFD?
For
Excuse me! I have some problems for emc2 installation. Today I have stalled the
ubuntu 8.04LTS system,after i connect a net i have installed the
emc2-install.sh software,but after i reboot my computer i click the cnc-emc2
software,the tip shows that EMC2 requires the real_time
12 matches
Mail list logo