Chris,
WWEEE - Yes the var file is writable. It helps a LOT when the ini file
specifies the CORRECT var file. The ini file had a full path to the var
file. Too bad the path was to a different directory. That directory is not
writable from the machine account. ugh
I removed the path. It is w
On Wed, Nov 04, 2009 at 11:53:07AM -0600, Stuart Stevenson wrote:
> I think the control should show X20. Y20. Z20..
I followed your instructions and it did in fact give me X20 Y20 Z20.
I am using git master, version 6decec1b49
Is the var file in your configuration writable?
--
Gentlemen,
latest git pull -
I set the coordinates of the G54... offsets using the touch off button.
The values are remembered until I shut the control off.
There are values in each offset prior to touching off to set zero. When I
restart the control the values are reset to the prior values.