On Sat, 10 Apr 1999, Greg Lehey wrote:
...
> In fact, it's not necessary. It happens any time you detach the last
> subdisk from a striped or RAID-5 plex.
Ups...
> Correct. What happened to the stack traces? Don't bother, though,
> I've reproduced it here. Expect a fix in a couple of hours.
Sor
On Saturday, 10 April 1999 at 4:05:10 +0200, Michael Reifenberger wrote:
> On Sat, 10 Apr 1999, Greg Lehey wrote:
>>> The panic occurs only, if I first use the incorrect config file with
>>> 'stripe', then the corrected one with 'striped' and then detaching
>>> the plex and the subdisks.
>
> This
On Sat, 10 Apr 1999, Greg Lehey wrote:
...
> It looks like you have them now, but you didn't then.
Strange, I'm shure I haven't touched them.
>
> > The only fault where the misspelling of 'stripe' versus 'striped' in
> > the configfile!
>
> That's not what your error messages are trying to tel
[Format recovered--see http://www.lemis.com/email/email-format.html]
On Saturday, 10 April 1999 at 3:37:47 +0200, Michael Reifenberger wrote:
> On Sat, 10 Apr 1999, Greg Lehey wrote:
> ...
>> You need to configure it. Use disklabel -e.
>
> No, they where configured.
> I have one ' d: 17848151
On Sat, 10 Apr 1999, Greg Lehey wrote:
...
> You need to configure it. Use disklabel -e.
No, they where configured.
I have one ' d: 17848151 63 vinum' slice per drive.
The only fault where the misspelling of 'stripe' versus 'striped' in the
configfile!
...
> Not much of anything,
On Friday, 9 April 1999 at 15:01:51 +0200, Michael Reifenberger wrote:
> Hi,
> next try.
> Please forgive if gets too stupid :-)
>
> # cat x
> drive d1 device /dev/da1d
> drive d2 device /dev/da2d
> volume raid
> plex org stripe 256k
> sd length 50m drive d1
> sd length 50m drive d2
> (please