Re: panic: integer divide fault with vinum

1999-04-10 Thread Michael Reifenberger
On Sat, 10 Apr 1999, Greg Lehey wrote: ... > In fact, it's not necessary. It happens any time you detach the last > subdisk from a striped or RAID-5 plex. Ups... > Correct. What happened to the stack traces? Don't bother, though, > I've reproduced it here. Expect a fix in a couple of hours. Sor

Re: panic: integer divide fault with vinum

1999-04-09 Thread Greg Lehey
On Saturday, 10 April 1999 at 4:05:10 +0200, Michael Reifenberger wrote: > On Sat, 10 Apr 1999, Greg Lehey wrote: >>> The panic occurs only, if I first use the incorrect config file with >>> 'stripe', then the corrected one with 'striped' and then detaching >>> the plex and the subdisks. > > This

Re: panic: integer divide fault with vinum

1999-04-09 Thread Michael Reifenberger
On Sat, 10 Apr 1999, Greg Lehey wrote: ... > It looks like you have them now, but you didn't then. Strange, I'm shure I haven't touched them. > > > The only fault where the misspelling of 'stripe' versus 'striped' in > > the configfile! > > That's not what your error messages are trying to tel

Re: panic: integer divide fault with vinum

1999-04-09 Thread Greg Lehey
[Format recovered--see http://www.lemis.com/email/email-format.html] On Saturday, 10 April 1999 at 3:37:47 +0200, Michael Reifenberger wrote: > On Sat, 10 Apr 1999, Greg Lehey wrote: > ... >> You need to configure it. Use disklabel -e. > > No, they where configured. > I have one ' d: 17848151

Re: panic: integer divide fault with vinum

1999-04-09 Thread Michael Reifenberger
On Sat, 10 Apr 1999, Greg Lehey wrote: ... > You need to configure it. Use disklabel -e. No, they where configured. I have one ' d: 17848151 63 vinum' slice per drive. The only fault where the misspelling of 'stripe' versus 'striped' in the configfile! ... > Not much of anything,

Re: panic: integer divide fault with vinum

1999-04-09 Thread Greg Lehey
On Friday, 9 April 1999 at 15:01:51 +0200, Michael Reifenberger wrote: > Hi, > next try. > Please forgive if gets too stupid :-) > > # cat x > drive d1 device /dev/da1d > drive d2 device /dev/da2d > volume raid > plex org stripe 256k > sd length 50m drive d1 > sd length 50m drive d2 > (please