> Sorry about all of the confusion. Basically, the answer to this
> depends on what exactly you're doing. (I should really write all of
> this up in a tutorial soon). The way I think about it is that there
> are two fundamental principles you need to keep in mind, and you can
> do it any way you ca
After previous discussions that suggested separating vdw and charge mutations,
I thought
it was literally a 2 stage process. In one stage I modify all charges
(including those
for disappearing atoms going to zero) from their starting values to their final
values,
using 10 lambda points and no so
>From my browsing of list archives I can only recall seeing advice that
>hyperthreading
cannot offer more Gromacs performance. For all I know this remains true if
you're trying
to use MPI to accelerate single calculations on hyperthreaded processors.
However, I
have discovered that it may be pos
Hi Bharat,
This is the same tutorial that led me astray when I first began trying free
energy
calculations in Gromacs. I am not sure how close to the experimental value the
author
intended to get with this hydration free energy tutorial. If you are using a
recent
version of Gromacs, be aware th
David, I forgot to ask:
You said that
" the soft core settings that work well for the vdW portion make the charging
portion a
more "difficult" transformation than normal, and the settings that work well for
charging make the vdW portion "difficult". "
What settings would you initially suggest t
David and Berk,
I enormously appreciate your help in diagnosing my free energy problems. Berk,
when you
said "I had implemented the alpha=1 option in 3.3 and set it as default" I
presume you
mean the sc_power=1 option, yes? David, when you talk of splitting the vdW and
charge
mutations into sep
Greetings once again fellow Gromacs-users,
I have seen a substantial and disturbing change in calculated free energy
differences
between systems run with Gromacs 3.3 and Gromacs 3.3.1. I am trying to
determine if
these differences are due to the new software, new parameters, insufficient
sampli
Hello fellow Gromacs-users,
Today I was extracting PDB snapshots from a solvated DNA 12mer simulation
trajectory.
When I went to view the snapshots, I saw that one of the DNA strands suddenly
jumped
some nanometers away from its partner during certain frames. I remembered that
there was
a note
Yes, I did make distclean before configuring with MPI enabled.
Matt Ernst
Washington State University
> [EMAIL PROTECTED] a écrit :
>> Hello,
>>
>> I have successfully built Gromacs 3.3.1 under Linux/Itanium 2 with the
>> following
>> configure options:
>>
>> ./configure -with-fft=fftw3 --withou
file or directory
make[5]: *** [libnb_kernel_ia64_single.la] Error 1
make[5]: Leaving directory
`/home/mernst/gromacs-3.3.1/src/gmxlib/nonbonded/nb_kernel_ia64_single'
make[4]: *** [all-recursive] Error 1
make[4]: Leaving directory `/home/mernst/gromacs-3.3.1/src/gmxlib/nonbonded'
make[3]
10 matches
Mail list logo