On 11/3/13 6:20 AM, kiana moghaddam wrote:
Dear Justin
Further to your previous email, I want to calculate free energy for DNA-ligand
interaction. According to your answer, for more sensitive calculations like free
energy simulations and normal modes, emtolshould be lower than 1. As
I
Hi GMX Users
I 'm running MD Simulation for DNA-ligand interaction. I ran energy
minimization with emtol=10, 100 and 250 in 1 steps (steepest descent
followed by the conjugate gradient algorithm). The lowest value for energy
obtained for emtol=10.
I have some questions about energy
On 11/2/13 3:38 PM, kiana moghaddam wrote:
Hi GMX Users
I 'm running MD Simulation for DNA-ligand interaction. I ran energy
minimization with emtol=10, 100 and 250 in 1 steps (steepest descent
followed by the conjugate gradient algorithm). The lowest value for energy
obtained for
Hi ,
I have a protein with 2 chains. I need to do normal mode analysis on it.
As there are no
covalent bonds between the two chains, I did not use the merge option in the
pdb2gmx
command.
I am trying to energy minimize the structure , in vaccum.( in double precision)
, but am not
able
February 2010 12:06 AM
To: gmx-users@gromacs.org
Subject: [gmx-users] energy minimization problem
Hi ,
I have a protein with 2 chains. I need to do normal mode analysis on it. As
there are no
covalent bonds between the two chains, I did not use the merge option in the
pdb2gmx
command.
I am
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of David van der Spoel
Sent: Sunday, June 24, 2007 4:18 AM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization problem with Double precision
andmpi
Josiah Zayner wrote
Josiah Zayner wrote:
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of David van der Spoel
Sent: Sunday, June 24, 2007 4:18 AM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization problem with Double precision
andmpi
Josiah
I managed to install mdrun_d from CVS and the problem is fixed
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of Josiah Zayner
Sent: Saturday, June 23, 2007 1:05 PM
To: gmx-users@gromacs.org
Subject: [gmx-users] Energy minimization problem with Double
Each time I try to run mdrun with double precision and more than one node, I
always receive some atom with infinite Fmax, no matter what I do, Always on
Step=0. The strangest thing is that it still attempts the minimization but
the values never change except for Dmax in a steepest descent. If I
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of David van der Spoel
Sent: Saturday, June 23, 2007 4:36 PM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization problem with Double precision
andmpi
Josiah Zayner wrote:
I
Dear gmx-users:
I am trying to simulate a surfactant-water
system(also contains some co-surfactants). Surfactant is a cationic
surfactant with chloride as counterion. And the cosurfactant is fatty
alcohol. water is of spc model. I got topologies from Prodrg for my
Hi Arun,
You have to get your methods straight.., and be more clear in the
phrasing of your question.
I am trying to simulate a surfactant-water
system(also contains some co-surfactants). Surfactant is a cationic
surfactant with chloride as counterion. And the
19 apr 2007 kl. 03.45 skrev Venky Krishna:
Hi George,
I usually delete/move the molecules reported to have high force
values in the minimization steps. A better thing would be to start
with a box which has sufficient intermolecular distance again by
deleting molecules which are very
Thanks guys for your replies. The problem is that the potential energy
is too low: it can't be true I think. Also, the high force means that
the system is not really stable (at least the atom influenced by this
force is not!). And yes I defined flexible for the water molecules.
I don't know if
George Abadir wrote:
Thanks guys for your replies. The problem is that the potential energy
is too low: it can't be true I think. Also, the high force means that
the system is not really stable (at least the atom influenced by this
force is not!). And yes I defined flexible for the water
Hi,
I am doing an energy minimization for a carbon nanotube (end capped
with hydrogen atoms) in a box of water. I get the following message:
Stepsize too small, or no change in energy.
Converged to machine precision,
but not to the requested precision Fmax 10
Double precision normally
Hi George,
I usually delete/move the molecules reported to have high force
values in the minimization steps. A better thing would be to start
with a box which has sufficient intermolecular distance again by
deleting molecules which are very close to each other (use the
g_mindist program)
On Mon, 17 Apr 2006 08:21:35 -0400 (EDT)
Robson P. S. Peguin [EMAIL PROTECTED] wrote:
Hi everybody,
I'm trying to simulate an interfacial system using
Gromacs. My simulation box has water in one side and
hydrofluorocarbon in the other side. This system was
successfully tested using DL-POLY
18 matches