From my experience its fine, the main problems are annoying changes to gedit, other side software and a few bugs that pop up, as the come out with a new release rather quickly...I usually avoid the new releases for at least 6 months now, and havnt really had much problem with larger bugs, such as
Dear All,
I am trying to generate .top file for my system. I would be obliged if you
could explain following topology file question to me, since it is not very
clearly mentioned anywhere:
In LAMMPS software that I am used to, user is required to enter details of
topology for all the molecules of
Dear All,
I am a new user of gromacs, and I want to use gromacs on MIC.
Recently I see the gromacs-5.0beta2 published, and in the lists of rebision
changes, I see it has been added the SIMD supported for Intel MIC.
But when run the gromacs on MIC, it doesn't use the MIC card.
On the other
Dear Gmx Users,
I am running REMD of a small protein in water. I have 36 temperatures.
After minimization I equilibrate each with nvt and npt ensemble. Then I
start REMD with -multidir. The mdp:
; Run parameters
integrator = md; leap-frog integrator
nsteps = 5000
dt =
Dear Andrea,
I've simulated a protein dimer for a long time span and now I need to
perform MM-PBSA calculations to get the binding free energy between the two
monomers.
Could you please send me the script to carry out this calculation.
I've read your paper Exploring PHD Fingers and H3K4me0
Dear all,
I am working with an homology model of a protein inserted in a POPC membrane.
I first ran minimization on the system, which ended up with I think
reasonable values for Fmax and Epot:
Steepest Descents converged to Fmax 1000 in 1390 steps
Potential Energy = -1.2822042e+06
Maximum force
Hi everybody,
I am running a simulation of a protein bonded on a metallic structure. In
the mdp files of the MD run I have set
constraints = none
while during the equilibration I had set
constraints = all-bond
in order to reach the MD step with the structure of my protein still in
order.
Dear All,
I am attempting to make modifications to the Gromos 53A6 forcefield in order to
implement the Gromos 56Acarbo forcefield in GROMACS. Most of the modifications
are straightforward except for some of the LJ parameters. As well as simple
adjustments to most of the 1-4 interaction
Hello,
I am trying to carry out a 2D PMF calculations of two ions in a peptidic
channel using GROMACS (and Umbrella Sampling).
I have several technical questions:
-Should I consider pull_ngroups= 3 (two of them ions and the other one the
channel)?
-Or
should I carry out a 1D PMF for one
On April 24, May 5, and May 11, I have received messages
with the subject, You have been unsubscribed from the
gromacs.org_gmx-users mailing list.
These e-mail do not have any text to them at all.
I immediately resubscribe myself only to receive another
the following week. I do not believe that I
Dear Gromacs users,
It seems that with the next Gromacs release (version 5) a new trajectory
format (TNG) is released
On 5/11/14, 2:01 PM, Chetan Mahajan wrote:
Thanks, Justin. I was also under impression that with com option,
distance between slab atoms (which are position restrained) remains same,
even though coordinates change. So doesn't it mean that TiO2 slab
dimensions should remain same?
No. Under
On 5/12/14, 2:43 AM, Chetan Mahajan wrote:
Dear All,
I am trying to generate .top file for my system. I would be obliged if you
could explain following topology file question to me, since it is not very
clearly mentioned anywhere:
In LAMMPS software that I am used to, user is required to
On 5/12/14, 5:32 AM, Floriane Montanari wrote:
Dear all,
I am working with an homology model of a protein inserted in a POPC membrane.
I first ran minimization on the system, which ended up with I think
reasonable values for Fmax and Epot:
Steepest Descents converged to Fmax 1000 in 1390
On 5/12/14, 6:14 AM, Nicola Staffolani wrote:
Hi everybody,
I am running a simulation of a protein bonded on a metallic structure. In
the mdp files of the MD run I have set
constraints = none
while during the equilibration I had set
constraints = all-bond
in order to reach the MD step
Hi,
The new TNG format and library do not affect other formats. So, if you
do not write/read TNG everything should work as before. There are some
TNG features that are not implemented yet in GROMACS, e.g. writing
energy data and/or other custom data. In a future version of GROMACS the
TNG
Hi Justin,
thank you for your clear reply!
However, it still comes as surprising to me that a standard N-H bond
(entered as a gb_2 one with the same parameters as described in Table
2.5.2.1 of the GROMOS96 Manual and User Guide) enters in conflict with the
standard dt value: indeed dt = 0.002 →
On 5/12/14, 9:03 AM, Nicola Staffolani wrote:
Hi Justin,
thank you for your clear reply!
However, it still comes as surprising to me that a standard N-H bond
(entered as a gb_2 one with the same parameters as described in Table
2.5.2.1 of the GROMOS96 Manual and User Guide) enters in
Bogdan, I had found that a little while ago but was unable to find again so
thankyou for pointing me to it again and writing it in the first place.
Jon, I hadn't found those file previously and they are consistent with what I
have come up with independently so I guess that is a good sign. Out
OK, got it, thanks a lot Justin! ;) .0005 ps is indeed working...
It is not clear to me what I miss - from the Chemistry or Physics point of
view - when I constraint the X-H bonds... I mean, will the rest of the
dynamics (for example, the oscillations of the other couples of bonded
atoms) be
On 5/12/14, 9:50 AM, Nicola Staffolani wrote:
OK, got it, thanks a lot Justin! ;) .0005 ps is indeed working...
It is not clear to me what I miss - from the Chemistry or Physics point of
view - when I constraint the X-H bonds... I mean, will the rest of the
dynamics (for example, the
Dear All,
I am using amber2gromacs tool acpype for converting input files for AMBER
into those for GROMACS. There are some differences in these files (.gro and
.top) compared to the information given in gromacs manual 4.6.5 abotu these
kind of files.
First, while listing charges and vander waals
gromacs is not giving error, but just wanted to confirm, especially the
first question. In absence of column for at.num, how would gromacs reading
my file know that second column is for mass? It's ofcourse commented as to
mass, but comments are not read anyways.
Thanks
Chetan
On Mon, May 12,
What would you recommend then? Equilibrate with Berendsen barostat and
v-rescale thermostat?
On Mon, May 12, 2014 at 2:01 PM, Justin Lemkul jalem...@vt.edu wrote:
On 5/12/14, 3:58 AM, Steven Neumann wrote:
Dear Gmx Users,
I am running REMD of a small protein in water. I have 36
I would generally encourage the use of NVT REMD. However, note that P-R
does exhibit unstable oscillatory behaviour when not close to equilibrium.
REMD is supposed to stay in equilibrium by design, but this gets double
crossed if the exchange period is too short with respect to the
autocorrelation
It was probably just a convenient number for whoever wrote the tool
originally.
Mark
On May 12, 2014 10:41 PM, Lalit upmu...@gmail.com wrote:
Hi All,
In the g_mindist calculations, the default distance for contacts is taken
as 0.6 nm. Is there a physical significance to this number? Why it
Thanks a lot! So which combination of thermostat/barostat would provide a
proper ensemble without crashes? I am looking in the literature but did not
find anything.
On Tue, May 13, 2014 at 6:34 AM, Mark Abraham mark.j.abra...@gmail.comwrote:
I would generally encourage the use of NVT REMD.
Thanks, Mark. With timestep to be 1 fs (instead of 2 fs) in production run,
job is running fine without blowing up. (equilibration run also contains
timestep to be 1 fs and refcoord-scaling option is set to com). However,
time step to 1 fs in production run does not affect water and its
Hi All,
In many papers, the authors cite the main gromacs paper and simply declare
in the methods section that they used the gromacs analysis suite. Is that a
good practice or should each tool be cited separately?
Eg: g_sas says:
PLEASE READ AND CITE THE FOLLOWING REFERENCE
Frank
29 matches
Mail list logo