Hi Kim,
I use Sigma V4630 in mouse tissue, but it is sold as an anti-human antibody
(but reactive to many species).
I use it at a dilution of 1:2500 with a PerkinElmer Cy3 TSA kit, with a Jackson
HRP-conjugated secondary.
Oh, before I forget, standard AR with citrate, pH 6.
Hope this helps.
Good Morning One and All,
Does anyone out there have any experience with the Beaker module of the LIS
system EPIC? We have tests that require tables and charts to be inserted
into the final report, pathologists need to have a case queue and other
items.
If you are using Epic/Beaker- please let
Can anyone give me information on their experience with the Ventana Symphony
stainer?
Nacaela
Sent from my iPhone
___
Histonet mailing list
Histonet@lists.utsouthwestern.edu
http://lists.utsouthwestern.edu/mailman/listinfo/histonet
We would interested in any replies as well.
Martha Ward, MT (ASCP) QIHC
Manager
Molecular Diagnostics Lab
Medical Center Boulevard \ Winston-Salem, NC 27157
p 336.716.2109 \ f 336.716.5890
mw...@wakehealth.edu
-Original Message-
From:
Hi,
There is a paper from 1972 (!) by Streefkerk entitled: Inhibition of
erythrocyte pseudoperoxidase activity by treatment with hydrogen peroxidase
following methanol. JHC 30:504. So perhaps the origin of methanol is not that
mysterious.
I cannot imagine that methanol is still considered for
Allied Search Partners is working with different laboratories in the state
of New York, looking for qualified and licensed Histotechnologists or
Histotechnicians.
To Apply Please email or fax resume to bran...@alliedsearchpartners.com
mailto:bran...@alliedsearchpartners.com or fax to 888 388
Dako is going to discontinue the ER , SP1 clone. We really want to use the SP1
clone, but do not want to use an ASR. We can get it from Ventana only we are
told. Can anyone elaborate on how they are handling this in their lab or if
they have switched to an ASR?
Thanks,
Leigh York
H202 mixed with Buffer here.(instead of aq.) That's OK too, right?
Right.
An addition to the misconceptions that Tim interestingly elucidates: some use
H2O2 in buffer because they think that , as the enzyme is performing a
physiologic catalytic reaction, it should be at a physiological pH, in
Hello all Listers,
I've already asked the Histonet but I'm wondering about a different thing
this time.
Does anyone have experience with Beaker in conjunction with Anatomic
Pathology, Surgical Pathology or the multiple other clinical labs that are
in hospitals today?
I work in Anatomic/Surgical
Fellow Histonetters:
Over the past few days there has been some discussion on this forum regarding
Biocare Medical's ability to continue offering the p63 antibody, some of which
has been correct and some of it incorrect. Please be assured that Biocare
still has the right to sell products that
From what I understand the SP1 Er clone has also been discontinued in USA by
Leica/Novacastra, I am told it is still being sold by Leica in Europe? Must
be another licensing issue because some are s greedy. I knew this was
going to happen and stock piled some of the ER SP1, but it won't last
I'm curious as to why all if a sudden some of these can be sold else where and
not in the USA. Is it a FDA issue?
Sent from my iPhone
On Jul 12, 2012, at 5:45 PM, Patsy Ruegg pru...@ihctech.net wrote:
From what I understand the SP1 Er clone has also been discontinued in USA by
It is most likely licensing issues between companies. A company may carry it
under license from another company but the terms change and the licensee either
loses the license (the other company won't license it), can't afford it or
other issues.
For example, when I worked in the antibody
Yea you are right Tim, I just wonder what ever happened to trying to get the
best ab for the patient, SP1 is in my opinion the best ER ab but now the
patient suffers because we can't use what is best for them, there is
something wrong with that picture.
Patsy Ruegg, HT(ASCP)QIHC
Ruegg Consulting