Re: An unexpected lights out operation

2006-05-14 Thread Bruno Sugliani
I guess it was a long time ago How do you proceed for electrical modification or maintenance without UPS ? How much is the insurance premium without UPS in your country ? ( in mine we don't even get an insurance without UPS ) We are even being obliged to use STS (source transfer system) on mono

Printing from a VTAM application to a TCP/IP printer

2006-05-14 Thread David Lesser
We have a VTAM application called EPS which send data to VTAM printers. Our new MF no longer has SNA devices, so we want these printouts to arrive at TCP/IP printers without changing EPS. We have made the following definitions : 1. In VTAM TCP VBUILD TYPE=APPL

Re: Need to report dataset allocation by volume

2006-05-14 Thread R.S.
Alfred Cole wrote: Hello, I am trying to create a report of all dataset by volume include the dataset space allocation. Could someone tell which utility I could use to list this information. I have tried using the IDCAMS listc. I would suggest IDCAMS DCOLLECT -- Radoslaw Skorupka Lodz,

Anyone have a good guess as to current number of z or 390 shops?

2006-05-14 Thread Phil Payne
With extreme trepidation as per 1 January 2006: z890 - around a thousand z990 - around two and a half thousand, perhaps a few more z9 - around 200 The surprise for me is how small some of them are. LOTS of tolerance and potential for errors. Worth less than you paid for it. -- Phil Payne

Re: Printing from a VTAM application to a TCP/IP printer

2006-05-14 Thread John S. Giltner, Jr.
David Lesser wrote: I would change DLOGMOD to SCS. This really does not matter, but it makes things less confusing. TRSPL017 APPL AUTH=NVPACE, X EAS=1, X PARSESS=NO,

Stupid SMF/SID Tricks (?)

2006-05-14 Thread Doc Farmer
Okay, here's the thing. I'm trying to clarify the SMF records so that each LPAR sends the records to a separate SYS1.LPARx.MANX/Y file. I've got the file naming down - FILE(SYS1.SID;.MANX,SYS1.SID;.MANY) - but I'm not sure if I can do multiple SID command in SMFPRM00. If I put all of the

Re: Stupid SMF/SID Tricks (?)

2006-05-14 Thread Shane Ginnane
Simple is best: DSNAME(SYS1.SYSNAME..MAN1, SYS1.SYSNAME..MAN2, SYS1.SYSNAME..MAN3) ... SID(SYSNAME) Let the system handle it. Shane ... -- For IBM-MAIN subscribe / signoff / archive

Re: ESCON Manager Replacement SA OS/390 V1R3 I/O-OPS function only?

2006-05-14 Thread Bruce Hewson
Hello Sam, Just letting you know I have been working 6 years without the ESCON Manager installed. Two sites each with 4 x 256 escon directors, and we have never noticed that we needed ESCON Manager. Regards Bruce Hewson --

Re: Stupid SMF/SID Tricks (?)

2006-05-14 Thread Doc Farmer
On Mon, 15 May 2006 13:11:06 +1000, Shane Ginnane [EMAIL PROTECTED] wrote: Simple is best: DSNAME(SYS1.SYSNAME..MAN1, SYS1.SYSNAME..MAN2, SYS1.SYSNAME..MAN3) ... SID(SYSNAME) Let the system handle it. Shane ... Simple? SIMPLE??? Where's the fun in

question to backup on 3590

2006-05-14 Thread Pohlen (Mailinglist)
Hi listers, I have a customer who backs up a data amount of about 500 GB with 2 Jobs each day on a 2-drives-3590 with DSS. Because of data growth, he has now problems with his batch window. His 3590 (A50/B11) is connected to his R36 by one escon channel. During the backup the channel is

Re: Stupid SMF/SID Tricks (?)

2006-05-14 Thread Bruce Hewson
Hello Doc, fyi, my SMF datasets are named this way. DSNAME(SYS1.SYSNAME..SMFDS1, SYS1.SYSNAME..SMFDS2, SYS1.SYSNAME..SMFDS3) Then everyone knows they belong to SMF, not the legacy MANX or MANY. Regards Bruce Hewson

Re: Migrating from OPS/MVS to AF/OPERATOR

2006-05-14 Thread Brian Westerman
Good Points, I have a problem with software that requires other software, but that's a whole different problem. There IS a lot of new software out there, but how much of it is actually necessary to get the job done, and at what cost? The concept that free software has associated costs because