http://www.bsp-gmbh.com/turnkey/cookbook/bsppilot.html
Possible automation on CBT tape 249, file 33.
Was rewritten for MVS 3.8 Turnkey project.
I was thinking BSP was licensed for non-commercial use, but I don't
see any distribution or licensing sites other than Turnkey 3. I did
see a message abou
Hi
I found the reason:
SDSF checks ISFAUTH *before* it looks at JESSPOOL.
Thanks a lot!
Best Regards,
Jason Cai
ibmnew pisze:
> Hi all
>
> My shop is z/OS 1.11(RACF).
>
> I want to know how to only purge and cancel own jobs from the SDSF pannels.
>
> SDSF,OPERCMDS and JESSPPOL cl
Hi Paul,
We use java also.
Especially since you can point SMPJHOME to something bogus and get the same
result, I would suggest checking to make sure that the DDDEF (or the JCL DD
card) and the pathname match and that it is mounted and that you can list the
directory in your hsf/zfs.
I can suggest Tivoli solutions.
--Original Message--
From: Renato Schweizer
Sender: IBM Mainframe Discussion List
To: IBM-MAIN@bama.ua.edu
ReplyTo: IBM Mainframe Discussion List
Subject: Replacement product for CA-Vantage
Sent: Mar 15, 2011 8:06 PM
Hello List
does anybody know a product
> does anybody know a product to replace CA-Vantage ? Should be a cheaper
one. Any
> suggestions ?
>
> Thanks
> Renato
>
I guess what function s do you need, want desire.
Vantage has many facilities that are integrated. So you should help us by
telling what specifically you need. There is no on
Hello
does anybody know a product to replace CA-Vantage ? Should be a cheaper
one. Any suggestions ?
Thanks
Renato
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the m
Hello List
does anybody know a product to replace CA-Vantage ? Should be a cheaper
one. Any suggestions ?
Thanks
Renato
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with
My test system has no ICSF; I'm trying to use the Java
surrogate. I get:
GIM45500S ** VERIFICATION OF HASH VALUE OF FILE .../package/GIMPAF.XML FAILED.
SMP/E WILL NOT RETRY FILE RETRIEVAL.
GIM20501IRECEIVE PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.
It's probably my
Jason,
I have used the following in SDSF where jobnamepattern is a pattern for
job names that you want to affect.
/$CJ(jobnamepattern)Cancel
/$PJ(jobnamepattern)Purge
For instance, to cancel all jobs starting with JG:
/$CJ(JG*)
There is also a user ID parameter.
Thanks again for everyone's help. If anyone cares, here is the assembler
program that reads the spanned file and creates a fixed length 136 byte file
padded with blanks where necessary. I don't claim to be the best assembler
programmer. I hope that worked in my favor in keeping it simple. But I
Hi Don,
Well said. I am not against change. But, at least in the land of the
mainframe, our careers focus on making and implementing changes that work, not
just to the developers' satisfaction, but to the satisfaction of our
customers. In this case, we are the customers. As long at SR is
Hi Timothy,
Case #1: Business as usual.
Business as usual has already been taken by the budget woes.
Case #2: Minimize the cost of overnight operators as much as possible
(through increased automation, alerting, etc.), and compare the cost of
that skeleton crew (of one?) to the likely s
Quite a deep hole SSA's dug itself into.
Interesting "According to a project plan released in August, the
facility will reach its maximum electrical distribution capacity within
four years", given increased mainframe efficiency and higher storage
densities.
---
"Social Security Confronts IT
All,
Just came across this today. PTF UA59179 to add SUDO support in USS
required GID(0) just to install it. I opened a ETR with IBM. The PTF
runs a script to do a CHGRP & CHOWN to UID/GID (0). Seems the port from
open source into USS requires GID (0).
We didn't have any profile with
That's a good way of explaining the issues. I agree.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of
Don Williams
Sent: Tuesday, March 15, 2011 11:21 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: ETR sunsets on 26 Mar 2011?
>From my informal p
This looks like it might be an issue on the Java side then. I don't want
to hijack to the dark side(java), but how are you defining the
connection?
RESTRICLOWPORTS should only apply to whoever opens port 514 for
listening, not whoever connects to it.
Antonio
-Original Message-
From: IBM
If you want to log messages from your Java application to the UNIX syslog, try
looking at this:
http://web.mit.edu/javadev/packages/Acme/Syslog.java
I even understood it, so it must be fairly simple!
--
John McKown
Systems Engineer IV
IT
Administrative Services Group
HealthMarkets(r)
9151
Thank you all for your help… To explain a little further…
I have a TCP/IP Socket port open to receive information and I am
attempting to write messages to the SYSLOG daemon (UDP port 514).
I have written this process in java.
Java gave a lot of error messages but the only one with meaning is
>From my informal poll, the vast majority of z/OS sysprogs agree with Jim.
They are not against change. It has been their job to implement change.
However, the change had to be non-disruptive to business.
The migration from PCP in 60's, to MFT, to MVT, etc. to z/OS today was 50
years of incrementa
I agree with Jim. Most of IBM's 'simplification' efforts have kept in mind the
experienced SYSPROGs and tried to give us the opportunity to maintain the touch
and feel of the old ways while giving the newer folks the touch and feel of the
web-based apps. So far I have seen each change in the ETR
Christian,
You made this comment in one of your emails:
SR processes roughly five times the service request volume of ETR today and is
designed to support a common IBM business process and customer work flow.
My comment to this is: So what if it handles 5 times the request volume if it
is unusab
This is certainly do-able. Please be aware that migration
coexistence/fallback support is not available.
Whatever technique is used to migrate from 1.7 to 1.11 will be required
in the reverse direction if needed to go back from 1.11 to 1.7
That being said, download all of the migration guides (1.7
Mostafa
There's one topic which will give you a big shock if you haven't dealt with it
already.
If you run a TN3270 server in the z/OS Communications Server (CS) IP
component, you need to make sure that you run
it as a separate address space in V1R11. Not supporting the TN3270 server
within
Dynamicly allocate or one output per file.
//OUTPUT1 OUTPUTCOPIES=1,PRMODE=LINE,ROOM=12,
// TITLE="TITLE ONE"
//TSTFILE1 DD SYSOUT=A,OUTPUT=(*.OUTPUT1)
Eh, where is this dynamic?
ok, once again, maybe I wasn't clear enough...
The JCL:
//OUTPUT2 OUTPUTCOPIES=1,PRMODE=LINE,ROOM=1
Hi,
We are currently in zOS 1.7 and we plan to migrate to 1.11.
Is there any hindrance or complication to do this migration in one shot ?
What are the requisites and measures to take before this type of migration ?
Thanks very much.
ibmnew pisze:
Hi all
My shop is z/OS 1.11(RACF).
I want to know how to only purge and cancel own jobs from the SDSF pannels.
SDSF,OPERCMDS and JESSPPOL classes are involved.
Could you help me?
Any suggestion would be helpful!
Could you be more specific?
We don't know anything about yo
Hi all
My shop is z/OS 1.11(RACF).
I want to know how to only purge and cancel own jobs from the SDSF pannels.
SDSF,OPERCMDS and JESSPPOL classes are involved.
Could you help me?
Any suggestion would be helpful!
Best Regards,
Jason Cai
-
27 matches