Validating SMP/E maintenance levels

2006-01-06 Thread McKown, John
I ran into a rather unusual problem yesterday. My SMP/E is lying to me. I did a REPORT CROSSZONES to determine what maintenance is on my test z/OS 1.4 system versus my production z/OS 1.4 system. I know that they are at different maintenance levels because some of the ISMF panels are different and

Re: Validating SMP/E maintenance levels

2006-01-06 Thread Matthew Stitt
This is where I use system symbolics. I load the master catalog with SYSR1 for the primary IPL volume (except for sys1.parmlib if it is on there) and use SYSR2, etc for the subsequent volumes. I then set the symbolics in the IEASYMxx member (except for SYSR1) and IPL. Works great except for