Haven’t used NA. But will look into it. Thk u.
Politics: Poli (many) - tics (blood sucking parasites)
On Wed, May 22, 2024 at 2:50 AM Rob Scott <
0618c90e6fdf-dmarc-requ...@listserv.ua.edu> wrote:
> Roberto
>
> Are there fields on this operator command that are not returned by the
> SDSF "N
On Wed, 22 May 2024 06:53:56 +, Rob Scott wrote:
>
>You can use the SDSF REXX interface to extract information from the DA panel
>and then use "address TSO EXECIO" to write the required output to a known
>DDname which could specify a GDG.
>
>You could then either schedule JCL to run this REXX
My Apologies Kolusu for wrong details inputted
Thanks Much for the sample job and it is working good for my requirement.
Regards
Ron T
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@
Good morning!
The Connect Direct set of cards below will compress the file during transfer to
the destination and then extract the file at the destination.
SIGNON CASE=YES
SUBMIT PROC=COPYDISK &COMPRESS=COMPRESS -
SNODE=SFGTST SNODEID=(ABCDE,123stu456) -
So, for various reasons, mostly for ease of management, we have maintained a
single volume sysres. Today they are non-sms mod-54’s. But alas, based on our
product mix, I am close to exceeding the capacity of a -54.I am looking to
move to EAV volumes, which z/OS supports, and my storage tea
How about allocating 'filler' data sets to fill up the empty space below
the EAS on the EAV? We did this once to force allocation in the EAS, but we
were not allocating ZFS files up there.
Mike Shaw
MVS/QuickRef Support Group
Chicago-Soft, Ltd.
On Wed, May 22, 2024 at 12:43 PM Jousma, David <
00
Actually, I just did a DFDSS logicial copy, and looks like there are smarts
built-in….My cloning process first copies all non-ZFS data, and then copies all
ZFS data after that. Looks like all the VSAM files landed in EAS space by
default even though EATTR isn’t specified on the datasets, and t
XPOST to CICS and IBM-MAIN
I have a program that does an EXEC CICS LINK to another program that issues
EXEC CICS ABEND.
CICS then generates a 4088/0063
I notice that the R12 in the program issuing the abend is a CAA, but it is
different than the CAA pointed to out of the TCA. Does EXEC CICS
What are you trying to accomplish by not de-compressing the file on
the receiving system?
Michael
At 09:12 AM 5/22/2024, Sasso, Len wrote:
Good morning! The Connect Direct set of cards below will compress
the file during transfer to the destination and then extract the
file at the destination
>On Tue, 21 May 2024 15:01:12 + "Schmitt, Michael"
> wrote:
>
>:>3. Depends on the language. IMS can have variable length segments but not=
> variable length fields, so any variable length fields are defined by the a=
>pplication. If the application is in COBOL, there's no native variable leng=
Sounds like you don't have PH24895 applied. The program issued abend
causes syncpoint rollback, which then drives the TRUE exits that are
registered for sync. LE is getting the TRUE RSA instead of for the last
EXEC CICS call. Fixed by PH24985.
On Thu, May 23, 2024 at 4:46 AM Binyamin Dissen
wr
Yes. You can either run compression in a run task, and then send
the resulting file to the target system, OR you can compress it
via a z/OS job and then have C:D pick up the resulting file and
send it.
The receiving site, if they are going to use it, must know what
you used for compression.
Well, NVIDEA reported earnings tonight and the growth was off the charts.
Growth never seen before. And no evidence of slowing down. Actually
accelerating. So much for the deniers.
Nvidia shows no signs of AI slowdown after over 400% jump in data center revenue
https://www.cnbc.com/2024/05/22/nv
All major relational databases support variable length data load (incl.
DB2) . This is not a problem at all.
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Wed, May 22, 2024 at 11:41 PM Tom Ross