ce one CF with another (section "Upgrading or replacing a
coupling facility").
Bill Neiman
IBM Parallel Sysplex Development
On Fri, 21 Jul 2023 16:13:04 -0500, Bonnie Barthel
wrote:
>A couple of questions...
>
>In the past few years using MAINTMODE START and STOP, I'
ick an INITSIZE value for which the default 75% value of MINSIZE could be
expressed in 1M (like 152M), you would see all the sizes displayed in 1M.
Bill Neiman
IBM Parallel Sysplex Development
On Wed, 5 Jul 2023 10:54:28 +, Mark Jacobs
wrote:
>I recreated the abnormality on our s
sults as the utility?
Bill Neiman
z/OS Parallel Sysplex development
On Thu, 29 Jun 2023 12:48:59 +, Mark Jacobs
wrote:
>718 STRUCTURE NAME(R901_GBP22) INITSIZE(150M) SIZE(293M)
>719PREFLIST(CFANB,CFBNB) REBUILDPERCENT(1) ALLOWAUTOALT(YES)
>
>ADMINI
Mark,
If you can supply an example of the input (CFRM policy) and output (IXCMIAPU
report) for one of the structures that provides output in units of K instead of
M, I'll take a look.
Bill Neiman
IBM Parallel Sysplex Develo
particular that for SIZER to be
helpful during migration, you must run it when both old and new CFs are
installed in the sysplex.
Bill Neiman
IBM Parallel Sysplex Development
--
For IBM-MAIN subscribe / signoff / archive access
The CLUSTER support was part of what was supposed to be an over-arching
automation infrastructure that would provide a sysplex-level view of properties
and events for improved business resiliency. I don't think it ever came
together.
Bill Neiman
Parallel Sysplex developmen
quarter, will alleviate this problem
somewhat.
Regards,
Bill Neiman
Parallel Sysplex development
IBM
> All,
>
> I can't reconcile RLS lock structure false lock contention between the
> various SMS statistics records.
>
> According to the type 42 subtype 17
uot;Understanding the Serialized
List Structure" and in the sections of that publication that describe the
various IXLLIST (IXLLSTE / IXLLSTM / IXLLSTC) request options.
Bill Neiman
z/OS Parallel Sysplex development
IBM
--
For IB
If you neglected to update CFRMPOL, then you will fall back to the wrong
policy and that's just the beginning of your troubles...
Bill Neiman
Parallel Sysplex Development
IBM
--
For IBM-MAIN subscribe / signoff / archive
CFSizer will tell you what you need to know for sizing the CF structure, but
provides no information about other considerations for sizing the Logger
environment, like staging and log data sets. For that, refer to z/OS Setting
Up a Sysplex (SA23-1399)
(https://www-01.ibm.com/servers/resourceli
As Peter points out, the Sizer utility, rather than CFSizer, is the tool of
choice for resizing structures in anticipation of a CFLEVEL change. CFSizer
(https://www-01.ibm.com/support/docview.wss?uid=isg3T1027062) is appropriate
when you're introducing a new workload or changing a workload for
ught me by surprise so the redirects are still
working their way through the approval process. But I'll be working on getting
the various publications and websites that point to CFSizer updated with the
new URL. Sorry for the
FYI: The CFSizer website has moved to
http://www.ibm.com/support/docview.wss?uid=isg3T1027062. There are still a few
glitches in the implementation at the new site, but we hope to get those ironed
out over the next few days.
Bill Neiman
Parallel Sysplex development
IBM
Leo,
The sample JCL in SYS1.SAMPLIB(IXCDELUT) should do what you want.
Bill Neiman
Parallel Sysplex development
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists
z/OS started task control processing inserts the @GENSET@ SET statement when
processing a started JOB (as opposed to a procedure).
Bill Neiman
z/OS Parallel Sysplex development (but long ago, Scheduler development)
--
For IBM
All couple data sets contain the sysplex name and can only be used in a sysplex
of that name, so they all have to be reformatted to define them with the new
name. In the IXCL1DSU JCL:
DEFINEDS SYSPLEX(newname)
Bill Neiman
Parallel Sysplex development
IBM
ecause an undersized structure
can cause serious problems while it's practically impossible to go wrong by
moderately over-sizing a structure (assuming you don't exceed the CF's
available storage).
Bill Neiman
IBM Parallel Sysplex development
---
ic or
otherwise, without having a sysplex CDS in use.
Bill Neiman
Parallel Sysplex development
IBM
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INF
However, the GRS ISGLOCK structure does not support alter, and there is
therefore no need to specify an INITSIZE. Just specify SIZE for ISGLOCK.
Bill Neiman
Parallel Sysplex Development
IBM Poughkeepsie
--
For IBM-MAIN
. It's up to you to determine what size works
for your installation.
Bill Neiman
Parallel Sysplex development
IBM Poughkeepsie
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listser
html). It is useful when
you believe that your structures are already sized correctly for your current
workload and CFLEVEL, you are migrating to a new CFLEVEL, and you want to know
how big your structures have to be to preserve the same capacity in the new CF.
Bill Neiman
Parallel Sys