Re: [EXTERNAL] Re: CBU HMC activation - switching back

2021-12-06 Thread Jake Anderson
Mainframe Discussion List On Behalf > Of Attila Fogarasi > Sent: Sunday, December 5, 2021 3:13 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: [EXTERNAL] Re: CBU HMC activation - switching back > > Chernobyl took out a couple of datacenters, so 35 years DR is the current > record

Re: [EXTERNAL] Re: CBU HMC activation - switching back

2021-12-06 Thread Pommier, Rex
al Message- From: IBM Mainframe Discussion List On Behalf Of Attila Fogarasi Sent: Sunday, December 5, 2021 3:13 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: [EXTERNAL] Re: CBU HMC activation - switching back Chernobyl took out a couple of datacenters, so 35 years DR is the current record :) D

Re: CBU HMC activation - switching back

2021-12-05 Thread Attila Fogarasi
> From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf > of Roger Lowe [roger_l...@bigpond.com] > Sent: Saturday, December 4, 2021 10:06 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: CBU HMC activation - switching back > > On Sun, 5 Dec 2021 00:46

Re: CBU HMC activation - switching back

2021-12-05 Thread Seymour J Metz
u.edu/~smetz3 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of Roger Lowe [roger_l...@bigpond.com] Sent: Saturday, December 4, 2021 10:06 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: CBU HMC activation - switching back On Sun, 5 Dec 20

Re: CBU HMC activation - switching back

2021-12-04 Thread Attila Fogarasi
To answer Jake's original question, CBU can be deactivated at any time by command (either in z/OS, on HMC/SE, or by API, depending on your hardware model). That stops the licensing accrual for CBU (as well as limiting the MSU back to non-CBU value). Several ways to do it, the simplest is to vary

Re: CBU HMC activation - switching back

2021-12-04 Thread Roger Lowe
On Sun, 5 Dec 2021 00:46:34 +, Seymour J Metz wrote: >Isn't a real DR usually temporary? > > >-- >Shmuel (Seymour J.) Metz >http://mason.gmu.edu/~smetz3 > CBU Test last only for 10 days whereas a CBU for an actual DR can last for up to 90 days... Roger -

Re: CBU HMC activation - switching back

2021-12-04 Thread Seymour J Metz
PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: CBU HMC activation - switching back That happened to us once (person replied that it was a real DR instead of a test). We contacted IBM right away and they fixed the CBU settings and didn't charge us. On 12/4/2021 6:41 AM, Jake Anderson wrote: >

Re: CBU HMC activation - switching back

2021-12-04 Thread Stuart Holland
That happened to us once (person replied that it was a real DR instead of a test). We contacted IBM right away and they fixed the CBU settings and didn't charge us. On 12/4/2021 6:41 AM, Jake Anderson wrote: Hello Is it possible to swtich back to temporary CBU activation incase it someone has

Re: CBU HMC activation - switching back

2021-12-04 Thread Radoslaw Skorupka
W dniu 04.12.2021 o 13:41, Jake Anderson pisze: Hello Is it possible to swtich back to temporary CBU activation incase it someone has activated the CBU permanently by mistake ? There are two modes of CBU Test and Real Activation. Test can be switched back at any time you want or it will be bac

Re: CBU HMC activation - switching back

2021-12-04 Thread Richards, Robert B. (CTR)
Check with IBM in any case. You'll need their involvement. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Jake Anderson Sent: Saturday, December 4, 2021 7:41 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: CBU HMC activation - switching back Hello Is it possib

CBU HMC activation - switching back

2021-12-04 Thread Jake Anderson
Hello Is it possible to swtich back to temporary CBU activation incase it someone has activated the CBU permanently by mistake ? Jake -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@list