Re: IEE313I when varying a console online

2013-09-15 Thread efinnell15
CF CHP(xx),offline then CF CHP(xx),online should clear all the status bytes and if operational the Consoles should come online. In a message dated 09/15/13 05:26:51 Central Daylight Time, gad...@malam.com writes: Could this be causing my problems --

Re: IEE313I when varying a console online

2013-09-15 Thread Bill Bishop (TEMA TPC)
ginal Message- From: Bill Bishop (TEMA TPC) [mailto:bill.bis...@tema.toyota.com] Sent: Thursday, September 12, 2013 5:15 PM To: גדי בן אבי; IBM Mainframe Discussion List Subject: RE: IEE313I when varying a console online It has been several years since I did these so I had to remember where all t

Re: IEE313I when varying a console online

2013-09-15 Thread גדי בן אבי
Bill Bishop (TEMA TPC) [mailto:bill.bis...@tema.toyota.com] Sent: Thursday, September 12, 2013 5:15 PM To: גדי בן אבי; IBM Mainframe Discussion List Subject: RE: IEE313I when varying a console online It has been several years since I did these so I had to remember where all this info was. There

Re: IEE313I when varying a console online

2013-09-12 Thread Bill Bishop (TEMA TPC)
IBM Mainframe Discussion List Cc: Bill Bishop (TEMA TPC) Subject: RE: IEE313I when varying a console online Hi Bill, I haven't seen any mention of a /con parameter in the documentation I have. Gadi -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.

Re: IEE313I when varying a console online

2013-09-12 Thread Peter Fatzinger
System command D C,U=xxx will show you if console services believes there is a console defined for that device. There's also a Redbook for the 2074 (http://www.redbooks.ibm.com/abstracts/sg245966.html) which may help. Peter Fatzinger ---

Re: IEE313I when varying a console online

2013-09-12 Thread גדי בן אבי
@LISTSERV.UA.EDU Subject: Re: IEE313I when varying a console online In , on 09/11/2013 at 06:35 PM, ÔÒÚ ß ÓßÚ said: >When I try to vary the device (V xxx,console) What is the status when you do a D U? Have you defined it as a console on that system? -- Shmuel (Seymour J.) Metz, SysProg and J

Re: IEE313I when varying a console online

2013-09-12 Thread Shmuel Metz (Seymour J.)
In , on 09/11/2013 at 08:49 PM, said: >Is is defined in the consolexx member. Did you IPL since chsnging the CONSOLxx member? Are you sure that you are using that member? -- Shmuel (Seymour J.) Metz, SysProg and JOAT Atid/2 We don't care. We don

Re: IEE313I when varying a console online

2013-09-12 Thread Shmuel Metz (Seymour J.)
In , on 09/11/2013 at 06:35 PM, ÔÒÚ ß ÓßÚ said: >When I try to vary the device (V xxx,console) What is the status when you do a D U? Have you defined it as a console on that system? -- Shmuel (Seymour J.) Metz, SysProg and JOAT Atid/2 We don't

Re: IEE313I when varying a console online

2013-09-11 Thread גדי בן אבי
-MAIN@LISTSERV.UA.EDU Subject: Re: IEE313I when varying a console online Do you have the /con entry in the parameters section of the 2074 definitions for the terminal being used as a console? Thanks Bill Bishop Specialist Mainframe Support Group Server Development & Support Toyota Motor Engineering &

Re: IEE313I when varying a console online

2013-09-11 Thread Bill Bishop (TEMA TPC)
yota.com (502) 570-6143 -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of ??? ?? ??? Sent: Wednesday, September 11, 2013 1:50 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: IEE313I when varying a console online Hi The answer is yes to both q

Re: IEE313I when varying a console online

2013-09-11 Thread גדי בן אבי
McKown [john.archie.mck...@gmail.com] Sent: 11 September 2013 18:59 To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: IEE313I when varying a console online Is the address specified exist in the I/O configuration? D U,,,,1 gives back valid information. If so, what is it's status? It needs to be OF

Re: IEE313I when varying a console online

2013-09-11 Thread Alan Field
LISTSERV.UA.EDU, Date: 09/11/2013 12:51 Subject: Re: IEE313I when varying a console online Sent by:IBM Mainframe Discussion List Hi The answer is yes to both questions. I can very it online, but I cannot vary console. The output from D U is O or OFFLINE. Is is defined in the c

Re: IEE313I when varying a console online

2013-09-11 Thread John McKown
Is the address specified exist in the I/O configuration? D U,,,,1 gives back valid information. If so, what is it's status? It needs to be OFFLINE before it can be varied as a CONSOLE. And it needs to be specified in the CONSOLxx member which was specified at IPL time. On Wed, Sep 11, 2013 at

Re: IEE313I when varying a console online

2013-09-11 Thread Alan Field
Is device xxx defined in the IOCDS. Is xxx defined in the CONSOLxx member. - Original Message - From: "גדי בן אבי" [gad...@malam.com] Sent: 09/11/2013 06:35 PM ZE3 To: IBM-MAIN@LISTSERV.UA.EDU Subject: IEE313I when varying a console online Hi, I am in the process of install

IEE313I when varying a console online

2013-09-11 Thread גדי בן אבי
Hi, I am in the process of installing a 2074 for a client. I know it's ancient, and unsupported, but everything this client has is ancient and unsupported. I managed to get a working console session on the 2074. When I try to configure PCOM, I get the 2074 index message. When I try to vary the