Re: New z/VM 5.3 VSWITCH Port Isolation function

2008-04-22 Thread Tracy J Adams
Hi, Wolfgang, There is nothing in the VSWITCH that will come up by default to prevent guests from talking to each other. If you send me your configuration information, I can take a look and see what might be going on.The default for a VSWITCH in z/VM 5.2 is DEFINE VSWITCH vswitchname

Re: Tracing VSWITCH - SAG broker problem

2007-04-11 Thread Tracy J Adams
the VSWITCH. Why the network folks don?t see it is a mystery to me. I have a few tests planned for Thursday morning which I hope will shed more light on the situation. Hans From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On Behalf Of Tracy J Adams Sent: April 10, 2007 2:36 PM To: IBMVM

Re: Tracing VSWITCH - SAG broker problem

2007-04-10 Thread Tracy J Adams
For more information on using the 'SNIFFER' support added in z/VM 5.2.0, please see the Troubleshooting a Virtual Switch or Guest LAN section of the z/VM Connectivity Guide. Tracy (Bolinda) Adams [EMAIL PROTECTED] z/VM Development - Virtual Networking Alan Altmark/Endicott/[EMAIL

Re: Unexpected DEFINE NIC Results

2007-01-11 Thread Tracy J Adams
Check your directory for NICDEFs and your MVSXExx users for error messages. I suspect you have a NICDEF or Define NIC with devices greater than 3. For example you could have a NICDEF 1340 type qdio devices 6 CP SEND does not show you the error message on your console but instead over on