Re: Diag A8 R15 RC of 3

2006-09-30 Thread Ken Vance
Hi, I talked to the devlopers today, and they said that they did not actually see a RC of 3, they just looked at the code and assumed that it had to be a 3. We have a program that restores data to a pack. It issues a DIAG A8, and then checks the codes. The code was setup in the past for

Re: Diag A8 R15 RC of 3

2006-09-27 Thread Alan Altmark
On Tuesday, 09/26/2006 at 04:21 AST, Ray Mansell [EMAIL PROTECTED] wrote: Ken, Can you tell us the level of CP where this happens, and the associated condition code? I've just spent an hour or so poring over the 5.2 source code for diag A8, and I can't see any way return code 3 can

Re: Diag A8 R15 RC of 3

2006-09-26 Thread Chris Langford
What CC on the DIAG A8 ? Whats in the CSW (Channel Status Word at int) ? What's in the sense ? Ken Vance wrote: Hi, We are using DIAG A8, and we are getting a RC of 3. This does not appear to be documented. We can see a condition code of 3, but not the R15 RC of 3. Has anyone seen

Re: Diag A8 R15 RC of 3

2006-09-26 Thread Ray Mansell
Ken, Can you tell us the level of CP where this happens, and the associated condition code? I've just spent an hour or so poring over the 5.2 source code for diag A8, and I can't see any way return code 3 can happen. Ray Mansell Ken Vance wrote: Hi, We are using DIAG A8, and we

Diag A8 R15 RC of 3

2006-09-26 Thread Ken Vance
Hi, We are using DIAG A8, and we are getting a RC of 3. This does not appear to be documented. We can see a condition code of 3, but not the R15 RC of 3. Has anyone seen documentation for this RC? Table 17. DIAGNOSE Code X'A8' Return Codes in the Guest's Register 15 with CC=1