Hi,
I talked to the devlopers today, and they said that they did not actually
see a RC of 3, they just looked at the code and assumed that it had to be
a 3. We have a program that restores data to a pack. It issues a DIAG
A8, and then checks the codes. The code was setup in the past for
On Tuesday, 09/26/2006 at 04:21 AST, Ray Mansell [EMAIL PROTECTED] wrote:
Ken,
Can you tell us the level of CP where this happens, and the associated
condition code? I've just spent an hour or so poring over the 5.2
source code
for diag A8, and I can't see any way return code 3 can
What CC on the DIAG A8 ?
Whats in the CSW (Channel Status Word at int) ?
What's in the sense ?
Ken Vance wrote:
Hi,
We are using DIAG A8, and we are getting a RC of 3. This does not
appear to be documented. We can see a condition code of 3, but not
the R15 RC of 3.
Has anyone seen
Ken,
Can you tell us the level of CP where this happens, and the associated
condition code? I've just spent an hour or so poring over the 5.2
source code for diag A8, and I can't see any way return code 3 can
happen.
Ray Mansell
Ken Vance wrote:
Hi,
We are using DIAG A8, and we
Hi,
We are using DIAG A8, and we are getting
a RC of 3. This does not appear to be documented. We can see
a condition code of 3, but not the R15 RC of 3.
Has anyone seen documentation for this
RC?
Table 17. DIAGNOSE Code X'A8' Return
Codes in the Guest's Register 15
with CC=1