One side must be CNC and the other must be ESCON_CTC. However, the
devices have to be right too. The CNC device must be defined without any
extra parms, while the ESCON_CTC side must be defined as CTCA EXT. I'll
attach the exec that finally worked for anyone who finds themselves in the
same
I'm trying to define an ESCON CTC between two of my VM LPARs on a z9.
Should be pretty straight forward, right? Well, I'm doing something
wrong as I cannot get them up. The chpids come online but the paths won't.
I've tried chpid type CNC and ESCON_CTC, but get the same result.
Does anyone have
I can't really
help there. Sorry.
Shimon
Original message
Date: Thu, 10 Jan 2008 13:28:13 EST
From: Martha McConaghy [EMAIL PROTECTED]
Subject: Dynamically defining ESCON CTC
To: IBMVM@LISTSERV.UARK.EDU
I'm trying to define an ESCON CTC between two of my VM LPARs
on a z9
Shimon,
Thanks for the suggestions. Of course, after posting to the list,
much learned advice from Rick Barlow, and
beating my head against the wall for awhile, I found the right combination.
One side must be CNC and the other must be ESCON_CTC. However, the
devices have to be right too. The