Dear Monica:
The Lytle database is not in a current standard format. I do have a
program to convert it but as Edmund has pointed out, you can find better
and more complete data set on the IXS database or just ask any one of us
who routinely run Ti edges at a synchrotron.
Carlo
On Tue, Jul 6,
As I recall, not only is the FL Dbase not in a standard format, but the
format varies according to the vintage of the files. Also, there's no
documentation except for the 1-line comment.
mam
On 7/6/2021 9:11 AM, Carlo Segre wrote:
Dear Monica:
The Lytle database is not in a current
Dear Monica,
the file you attached does not look like an ASCII file. Anyway, usually
the information you need to convert the steps into useful physical units
(degree-> energy) is in the header of the files in thew Lytle database.
Often not in a very clear form if I remember correctly...
You
Hello all:
I am looking forward to standard metal foil data of titanium.
I downloaded the data from the Farrel Lytle database but I can not
import it into Athena. I looked into the data, it looked wired for me.
As Athena expects data to be in columns of energy but this data is not
recorded by