that got it working it seems :)
Thanks guys!!!
On Tue, Feb 26, 2013 at 12:06 AM, Gordon Smith gor...@gswsystems.comwrote:
This (remote syslog) works for me on SRX550's running 12.1R1.9
This will apply a default deny log to the end of your security policies,
so you don't need to reorder
actually, i retract that statement.
i saw a deny come through, and it was logged, but under testing and further
review, it seems that the only thing this is logging is UDP to port 44082.
Any telnet testing to random ports do not generate logs, neither does using
internet sites to test port
Hello list,
Anybody have some good advice on AC to DC converters to power a Juniper T640
with dual input DC power supplies? I found a few vendors that do 4x50A in 1U
(TDK for example) and was wondering if anybody was using these in real life to
power T's.
Regards
Rutger
Does
anybody have experience with Accedian (www.accedian.com) equipments
interoperability with Juniper
equipments ?
I’m really
interested in experience having LAG (with LACP or OAM on top) configured
between MX in virtual-chassis (customer
side) and Accedian (metro Ethernet provider side --
We use Eltek-Valere. Work very well and reasonably priced.
On 02/26/2013 11:45 AM, Rutger Bevaart wrote:
Hello list,
Anybody have some good advice on AC to DC converters to power a Juniper T640
with dual input DC power supplies? I found a few vendors that do 4x50A in 1U
(TDK for example)
Hi folks,
If I need a quote for a couple of MX5, do I just call juniper sale up and
ask for a quote?
will it be cheaper to go through their resellers?
Thanks.
Regards,
-Luan
___
juniper-nsp mailing list juniper-nsp@puck.nether.net
Tyco/Lineage Power make a couple of products that I have used personally
for powering Juniper routers and other telco equipment.
There are two 1RU shelves that can take 4 rectifier bricks each, one made
to take 2kW rectifiers with 10A inputs, the other 2.7kW with 16A inputs.
The 10.8kW shelves I
To follow up: I called juniper and it turns out we are an elite partner :)
so I am all good. Just waiting for a quote with discount.
Regards,
-Luan
On Tue, Feb 26, 2013 at 2:55 PM, Luan Nguyen luan20...@gmail.com wrote:
Hi folks,
If I need a quote for a couple of MX5, do I just call
You will get referred to a Juniper partner no matter which route you take -
Juniper doesn't sell direct (except to some very large accounts).
Where are you located geographically?
Paul
-Original Message-
From: juniper-nsp-boun...@puck.nether.net
Thanks very much. So confirm, there is nothing that says one PIC will get
a certain amount at minimum right?
What determines what is dropped when there is contention on the bus? Are
there any commands I could use to see whether a bus is/was congested and
how much of what was dropped?
On Sat,
If you oversubscribe the bus you oversubscribe the bus. Traffic load
v.s. average packet size v.s. level of oversubscrip v.s. burstiness will
determine loss potential.
On 2/26/13 11:59 AM, Matt Bentley wrote:
Thanks very much. So confirm, there is nothing that says one PIC will
get a certain
Hi,
Does anyone know the equivalent of Cisco commands show dsl interface in
Junos.
I want to see the speed of DSL.
Regards,
*Ali Sumsam CCIE*
*Network Engineer - Level 3*
eintellego Pty Ltd
a...@eintellego.net ; www.eintellego.net
Phone: 1300 753 383 ; Fax: (+612) 8572 9954
Cell +61 (0)410 603
show interfaces at-1/0/0 extensive | match Bit
First column is your downstream sync, third column is your upstream.
On 27/02/2013, at 2:52 PM, Ali Sumsam ali+juniper...@eintellego.net wrote:
Hi,
Does anyone know the equivalent of Cisco commands show dsl interface in
Junos.
I want to see
Hi Ali,
You should be able to use the 'show interfaces interface-name extensive
command. Full DSL statistics are included in this output.
http://www.juniper.net/techpubs/software/junos-security/junos-security10.2/junos-security-swconfig-interfaces/jd0e20123.html
HTH,
Graham
On Wednesday,
14 matches