Tim,
thanks for the information. Without state change, I have to spend a
deeper look and try to recreate the problem here. This could take some
time since our servers all support the "READ SUBSYSTEM DATA" and I have
to workaround.
Stefan
Am 26.06.2012 16:56, schrieb Tim Full:
Thanks for the fe
Thanks for the feedback Stefan. I don't believe there is any state change
taking place. I contacted the vendor. The following was their response:
The Perform SubSystem Function ccw is asking for Order x18 SubOrder 0x0e.
The Order indicates a Read SubSystem Data is to follow, and the Suborder
in
Hi,
this looks like a BUG in handling of older DASD devices.
The query can not be easily disabled but I will have a look if we can
fix this for future releases.
At first sight this should only happen after a state change interrupt
and then unfortunately in a loop...
Stefan
Am 25.06.2012 02:49,
I'm running RHEL6.2 on an IBM z/Series z/114 under z/VM 5.4 with older dasd
that does not support 'READ SUBSYSTEM DATA" request for extended features.
Every 30 seconds, I get:
dasd(eckd): I/O status report for device 0.0.0100:
<3>dasd(eckd): in req: 025cef00 CC:00 FC:04 AC:00 SC:17 DS:0E C