Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-06-22 Thread Marek Grac
Hi, On 06/20/2011 07:16 AM, Parvez Shaikh wrote: Hi Thanks Dominic, Do fence_bladecenter "reboot" the blade as a part of fencing always? I have seen it turning the blade off by default. fence daemon always tries to reboot a machine. In most of the cases it is done by power off / check if

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-06-19 Thread Parvez Shaikh
Hi Thanks Dominic, Do fence_bladecenter "reboot" the blade as a part of fencing always? I have seen it turning the blade off by default. Through fence_bladecenter --missing-as-off.. -o off returns me a correct result when run from command line but fencing fails through "fenced". I am using RH

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-06-19 Thread dOminic
There is a bug related to missing_as_off - https://bugzilla.redhat.com/show_bug.cgi?id=689851 - expects the fix in rhel5u7 . regards, On Wed, Apr 27, 2011 at 1:59 PM, Parvez Shaikh wrote: > Hi all, > > I am using RHCS on IBM bladecenter with blade center fencing. I plugged out > a blade from b

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-06-14 Thread Parvez Shaikh
Hi, Has anyone used missing_as_off in cluster.conf file? Any help where to put this option in cluster.conf would be greatly appreciated Thanks, Parvez On Mon, May 2, 2011 at 6:49 PM, Parvez Shaikh wrote: > Hi Marek, > > I tried the option missing_as_off="1" and now I get an another error - > >

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-05-02 Thread Parvez Shaikh
Hi Marek, I tried the option missing_as_off="1" and now I get an another error - fenced[18433]: fence "node5.sscdomain" failed fenced[18433]: fencing node "node5.sscdomain" Sniplet of cluster.conf file is - Did I miss

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-05-02 Thread Marek Grac
Hi, On 04/29/2011 10:15 AM, Parvez Shaikh wrote: Hi Marek, Can we give this option in cluster.conf file for bladecenter fencing device or method for cluster.conf you should add ... missing_as_off="1" ... to fence configuration For IPMI, fencing is there similar option? There is no su

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-04-29 Thread Parvez Shaikh
Hi Marek, Can we give this option in cluster.conf file for bladecenter fencing device or method For IPMI, fencing is there similar option? On Fri, Apr 29, 2011 at 1:38 PM, Marek Grac wrote: > Hi, > > > On 04/27/2011 10:29 AM, Parvez Shaikh wrote: > >> Hi all, >> >> I am using RHCS on IBM blad

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-04-29 Thread Marek Grac
Hi, On 04/27/2011 10:29 AM, Parvez Shaikh wrote: Hi all, I am using RHCS on IBM bladecenter with blade center fencing. I plugged out a blade from blade center chassis slot and was hoping that failover to occur. However when I did so, I get following message - fenced[10240]: agent "fence_bla

[Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed

2011-04-27 Thread Parvez Shaikh
Hi all, I am using RHCS on IBM bladecenter with blade center fencing. I plugged out a blade from blade center chassis slot and was hoping that failover to occur. However when I did so, I get following message - fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain correct plu