Hi,
On 06/20/2011 07:16 AM, Parvez Shaikh wrote:
Hi Thanks Dominic,
Do fence_bladecenter "reboot" the blade as a part of fencing always? I
have seen it turning the blade off by default.
fence daemon always tries to reboot a machine. In most of the cases it
is done by power off / check if
Hi Thanks Dominic,
Do fence_bladecenter "reboot" the blade as a part of fencing always? I have
seen it turning the blade off by default.
Through fence_bladecenter --missing-as-off.. -o off returns me a correct
result when run from command line but fencing fails through "fenced". I am
using RH
There is a bug related to missing_as_off -
https://bugzilla.redhat.com/show_bug.cgi?id=689851 - expects the fix in
rhel5u7 .
regards,
On Wed, Apr 27, 2011 at 1:59 PM, Parvez Shaikh wrote:
> Hi all,
>
> I am using RHCS on IBM bladecenter with blade center fencing. I plugged out
> a blade from b
Hi,
Has anyone used missing_as_off in cluster.conf file?
Any help where to put this option in cluster.conf would be greatly
appreciated
Thanks,
Parvez
On Mon, May 2, 2011 at 6:49 PM, Parvez Shaikh wrote:
> Hi Marek,
>
> I tried the option missing_as_off="1" and now I get an another error -
>
>
Hi Marek,
I tried the option missing_as_off="1" and now I get an another error -
fenced[18433]: fence "node5.sscdomain" failed
fenced[18433]: fencing node "node5.sscdomain"
Sniplet of cluster.conf file is -
Did I miss
Hi,
On 04/29/2011 10:15 AM, Parvez Shaikh wrote:
Hi Marek,
Can we give this option in cluster.conf file for bladecenter fencing
device or method
for cluster.conf you should add ... missing_as_off="1" ... to fence
configuration
For IPMI, fencing is there similar option?
There is no su
Hi Marek,
Can we give this option in cluster.conf file for bladecenter fencing device
or method
For IPMI, fencing is there similar option?
On Fri, Apr 29, 2011 at 1:38 PM, Marek Grac wrote:
> Hi,
>
>
> On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
>
>> Hi all,
>>
>> I am using RHCS on IBM blad
Hi,
On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
Hi all,
I am using RHCS on IBM bladecenter with blade center fencing. I
plugged out a blade from blade center chassis slot and was hoping that
failover to occur. However when I did so, I get following message -
fenced[10240]: agent "fence_bla
Hi all,
I am using RHCS on IBM bladecenter with blade center fencing. I plugged out
a blade from blade center chassis slot and was hoping that failover to
occur. However when I did so, I get following message -
fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain
correct plu