Quoting Peng Fan (2019-09-08 20:39:39)
> From: Peng Fan
>
> When registering the PLL, unbypass the PLL.
> The PLL has two bypass control bit, BYPASS and EXT_BYPASS.
> we will expose EXT_BYPASS to clk driver for mux usage, and keep
> BYPASS inside pll14xx usage. The PLL has a restriction that
>
From: Peng Fan
When registering the PLL, unbypass the PLL.
The PLL has two bypass control bit, BYPASS and EXT_BYPASS.
we will expose EXT_BYPASS to clk driver for mux usage, and keep
BYPASS inside pll14xx usage. The PLL has a restriction that
when M/P change, need to RESET/BYPASS pll to avoid